Buderus Logatherm WLW176i-10 AR E (60°C)

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Logatherm WLW MB AR

Machine-readable: https://bedandbot.it/p/buderus-logatherm-wlw176i-10-ar-e-60-c.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application188 %HP Keymark 011-1W0584
“η s 188 % 142 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application172 %HP Keymark 011-1W0584
“η s 172 % 130 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application244 %HP Keymark 011-1W0584
“η s 244 % 171 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application142 %HP Keymark 011-1W0584
“η s 188 % 142 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application130 %HP Keymark 011-1W0584
“η s 172 % 130 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application171 %HP Keymark 011-1W0584
“η s 244 % 171 %”
Rated heat output (Prated)average climate, 35 °C application10 kWHP Keymark 011-1W0584
“Prated 10 kW 10 kW”
Rated heat output (Prated)colder climate, 35 °C application10 kWHP Keymark 011-1W0584
“Prated 10 kW 10 kW”
Rated heat output (Prated)warmer climate, 35 °C application10.6 kWHP Keymark 011-1W0584
“Prated 10.6 kW 9.8 kW”
Rated heat output (Prated)average climate, 55 °C application10 kWHP Keymark 011-1W0584
“Prated 10 kW 10 kW”
Rated heat output (Prated)colder climate, 55 °C application10 kWHP Keymark 011-1W0584
“Prated 10 kW 10 kW”
Rated heat output (Prated)warmer climate, 55 °C application9.8 kWHP Keymark 011-1W0584
“Prated 10.6 kW 9.8 kW”
Refrigerant charge—1.7 kgHP Keymark 011-1W0584
“Mass of Refrigerant 1,700 kg”
SCOPaverage climate, 35 °C application4.77 HP Keymark 011-1W0584
“SCOP 4.77 3.64”
SCOPcolder climate, 35 °C application4.36 HP Keymark 011-1W0584
“SCOP 4.36 3.33”
SCOPwarmer climate, 35 °C application6.18 HP Keymark 011-1W0584
“SCOP 6.18 4.34”
SCOPaverage climate, 55 °C application3.64 HP Keymark 011-1W0584
“SCOP 4.77 3.64”
SCOPcolder climate, 55 °C application3.33 HP Keymark 011-1W0584
“SCOP 4.36 3.33”
SCOPwarmer climate, 55 °C application4.34 HP Keymark 011-1W0584
“SCOP 6.18 4.34”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0584
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0584
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0584
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0584
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0584
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0584
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0584
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0584
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0584
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0584
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0584
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0584
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.