PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application183 %HP Keymark 011-1W0584
“η s 183 % 136 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application165 %HP Keymark 011-1W0584
“η s 165 % 127 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application233 %HP Keymark 011-1W0584
“η s 233 % 168 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application136 %HP Keymark 011-1W0584
“η s 183 % 136 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application127 %HP Keymark 011-1W0584
“η s 165 % 127 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application168 %HP Keymark 011-1W0584
“η s 233 % 168 %”
Rated heat output (Prated)average climate, 35 °C application12.2 kWHP Keymark 011-1W0584
“Prated 12.2 kW 12 kW”
Rated heat output (Prated)colder climate, 35 °C application12 kWHP Keymark 011-1W0584
“Prated 12 kW 12 kW”
Rated heat output (Prated)warmer climate, 35 °C application12.6 kWHP Keymark 011-1W0584
“Prated 12.6 kW 12.4 kW”
Rated heat output (Prated)average climate, 55 °C application12 kWHP Keymark 011-1W0584
“Prated 12.2 kW 12 kW”
Rated heat output (Prated)colder climate, 55 °C application12 kWHP Keymark 011-1W0584
“Prated 12 kW 12 kW”
Rated heat output (Prated)warmer climate, 55 °C application12.4 kWHP Keymark 011-1W0584
“Prated 12.6 kW 12.4 kW”
Refrigerant charge—1.7 kgHP Keymark 011-1W0584
“Mass of Refrigerant 1,700 kg”
SCOPaverage climate, 35 °C application4.64 HP Keymark 011-1W0584
“SCOP 4.64 3.48”
SCOPcolder climate, 35 °C application4.21 HP Keymark 011-1W0584
“SCOP 4.21 3.24”
SCOPwarmer climate, 35 °C application5.91 HP Keymark 011-1W0584
“SCOP 5.91 4.28”
SCOPaverage climate, 55 °C application3.48 HP Keymark 011-1W0584
“SCOP 4.64 3.48”
SCOPcolder climate, 55 °C application3.24 HP Keymark 011-1W0584
“SCOP 4.21 3.24”
SCOPwarmer climate, 55 °C application4.28 HP Keymark 011-1W0584
“SCOP 5.91 4.28”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0584
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0584
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0584
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0584
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0584
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0584
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0584
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0584
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0584
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0584
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0584
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0584
“TOL 2 °C 2 °C”