Buderus Logatherm WLW176i-4 AR E (60°C)

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Logatherm WLW MB AR

Machine-readable: https://bedandbot.it/p/buderus-logatherm-wlw176i-4-ar-e-60-c.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application180 %HP Keymark 011-1W0582
“η s 180 % 130 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application158 %HP Keymark 011-1W0582
“η s 158 % 109 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application210 %HP Keymark 011-1W0582
“η s 210 % 143 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application130 %HP Keymark 011-1W0582
“η s 180 % 130 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application109 %HP Keymark 011-1W0582
“η s 158 % 109 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application143 %HP Keymark 011-1W0582
“η s 210 % 143 %”
Rated heat output (Prated)average climate, 35 °C application4.4 kWHP Keymark 011-1W0582
“Prated 4.4 kW 4 kW”
Rated heat output (Prated)colder climate, 35 °C application3.8 kWHP Keymark 011-1W0582
“Prated 3.8 kW 3.2 kW”
Rated heat output (Prated)warmer climate, 35 °C application4.3 kWHP Keymark 011-1W0582
“Prated 4.3 kW 3.8 kW”
Rated heat output (Prated)average climate, 55 °C application4 kWHP Keymark 011-1W0582
“Prated 4.4 kW 4 kW”
Rated heat output (Prated)colder climate, 55 °C application3.2 kWHP Keymark 011-1W0582
“Prated 3.8 kW 3.2 kW”
Rated heat output (Prated)warmer climate, 55 °C application3.8 kWHP Keymark 011-1W0582
“Prated 4.3 kW 3.8 kW”
Refrigerant charge—0.95 kgHP Keymark 011-1W0582
“Mass of Refrigerant 0,950 kg”
SCOPaverage climate, 35 °C application4.58 HP Keymark 011-1W0582
“SCOP 4.58 3.32”
SCOPcolder climate, 35 °C application4.03 HP Keymark 011-1W0582
“SCOP 4.03 2.81”
SCOPwarmer climate, 35 °C application5.33 HP Keymark 011-1W0582
“SCOP 5.33 3.66”
SCOPaverage climate, 55 °C application3.32 HP Keymark 011-1W0582
“SCOP 4.58 3.32”
SCOPcolder climate, 55 °C application2.81 HP Keymark 011-1W0582
“SCOP 4.03 2.81”
SCOPwarmer climate, 55 °C application3.66 HP Keymark 011-1W0582
“SCOP 5.33 3.66”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0582
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0582
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0582
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0582
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0582
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0582
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0582
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0582
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0582
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0582
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0582
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0582
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.