Buderus Logatherm WLW176i-5 AR E (60°C)

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Logatherm WLW MB AR

Machine-readable: https://bedandbot.it/p/buderus-logatherm-wlw176i-5-ar-e-60-c.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application180 %HP Keymark 011-1W0582
“η s 180 % 137 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application167 %HP Keymark 011-1W0582
“η s 167 % 124 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application219 %HP Keymark 011-1W0582
“η s 219 % 157 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application137 %HP Keymark 011-1W0582
“η s 180 % 137 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application124 %HP Keymark 011-1W0582
“η s 167 % 124 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application157 %HP Keymark 011-1W0582
“η s 219 % 157 %”
Rated heat output (Prated)average climate, 35 °C application6.2 kWHP Keymark 011-1W0582
“Prated 6.2 kW 6.2 kW”
Rated heat output (Prated)colder climate, 35 °C application5.4 kWHP Keymark 011-1W0582
“Prated 5.4 kW 5.3 kW”
Rated heat output (Prated)warmer climate, 35 °C application6.4 kWHP Keymark 011-1W0582
“Prated 6.4 kW 5.9 kW”
Rated heat output (Prated)average climate, 55 °C application6.2 kWHP Keymark 011-1W0582
“Prated 6.2 kW 6.2 kW”
Rated heat output (Prated)colder climate, 55 °C application5.3 kWHP Keymark 011-1W0582
“Prated 5.4 kW 5.3 kW”
Rated heat output (Prated)warmer climate, 55 °C application5.9 kWHP Keymark 011-1W0582
“Prated 6.4 kW 5.9 kW”
Refrigerant charge—0.95 kgHP Keymark 011-1W0582
“Mass of Refrigerant 0,950 kg”
SCOPaverage climate, 35 °C application4.57 HP Keymark 011-1W0582
“SCOP 4.57 3.5”
SCOPcolder climate, 35 °C application4.25 HP Keymark 011-1W0582
“SCOP 4.25 3.17”
SCOPwarmer climate, 35 °C application5.56 HP Keymark 011-1W0582
“SCOP 5.56 4”
SCOPaverage climate, 55 °C application3.5 HP Keymark 011-1W0582
“SCOP 4.57 3.5”
SCOPcolder climate, 55 °C application3.17 HP Keymark 011-1W0582
“SCOP 4.25 3.17”
SCOPwarmer climate, 55 °C application4 HP Keymark 011-1W0582
“SCOP 5.56 4”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0582
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0582
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0582
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0582
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0582
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0582
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0582
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0582
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0582
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0582
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0582
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0582
“TOL 2 °C 2 °C”