Buderus Logatherm WLW176i-5 AR TP70

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Logatherm WLW MB AR

Machine-readable: https://bedandbot.it/p/buderus-logatherm-wlw176i-5-ar-tp70.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application179 %HP Keymark 011-1W0582
“η s 179 % 136 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application167 %HP Keymark 011-1W0582
“η s 167 % 123 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application218 %HP Keymark 011-1W0582
“η s 218 % 155 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application136 %HP Keymark 011-1W0582
“η s 179 % 136 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application123 %HP Keymark 011-1W0582
“η s 167 % 123 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application155 %HP Keymark 011-1W0582
“η s 218 % 155 %”
Rated heat output (Prated)average climate, 35 °C application6.2 kWHP Keymark 011-1W0582
“Prated 6.2 kW 6.2 kW”
Rated heat output (Prated)colder climate, 35 °C application5.4 kWHP Keymark 011-1W0582
“Prated 5.4 kW 5.3 kW”
Rated heat output (Prated)warmer climate, 35 °C application6.4 kWHP Keymark 011-1W0582
“Prated 6.4 kW 5.9 kW”
Rated heat output (Prated)average climate, 55 °C application6.2 kWHP Keymark 011-1W0582
“Prated 6.2 kW 6.2 kW”
Rated heat output (Prated)colder climate, 55 °C application5.3 kWHP Keymark 011-1W0582
“Prated 5.4 kW 5.3 kW”
Rated heat output (Prated)warmer climate, 55 °C application5.9 kWHP Keymark 011-1W0582
“Prated 6.4 kW 5.9 kW”
Refrigerant charge—0.95 kgHP Keymark 011-1W0582
“Mass of Refrigerant 0,950 kg”
SCOPaverage climate, 35 °C application4.55 HP Keymark 011-1W0582
“SCOP 4.55 3.47”
SCOPcolder climate, 35 °C application4.24 HP Keymark 011-1W0582
“SCOP 4.24 3.14”
SCOPwarmer climate, 35 °C application5.53 HP Keymark 011-1W0582
“SCOP 5.53 3.96”
SCOPaverage climate, 55 °C application3.47 HP Keymark 011-1W0582
“SCOP 4.55 3.47”
SCOPcolder climate, 55 °C application3.14 HP Keymark 011-1W0582
“SCOP 4.24 3.14”
SCOPwarmer climate, 55 °C application3.96 HP Keymark 011-1W0582
“SCOP 5.53 3.96”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0582
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0582
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0582
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0582
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0582
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0582
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0582
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0582
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0582
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0582
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0582
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0582
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.