PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application186 %HP Keymark 011-1W0584
“η s 186 % 141 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application170 %HP Keymark 011-1W0584
“η s 170 % 129 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application242 %HP Keymark 011-1W0584
“η s 242 % 168 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application141 %HP Keymark 011-1W0584
“η s 186 % 141 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application129 %HP Keymark 011-1W0584
“η s 170 % 129 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application168 %HP Keymark 011-1W0584
“η s 242 % 168 %”
Rated heat output (Prated)average climate, 35 °C application10 kWHP Keymark 011-1W0584
“Prated 10 kW 10 kW”
Rated heat output (Prated)colder climate, 35 °C application10 kWHP Keymark 011-1W0584
“Prated 10 kW 10 kW”
Rated heat output (Prated)warmer climate, 35 °C application10.6 kWHP Keymark 011-1W0584
“Prated 10.6 kW 9.8 kW”
Rated heat output (Prated)average climate, 55 °C application10 kWHP Keymark 011-1W0584
“Prated 10 kW 10 kW”
Rated heat output (Prated)colder climate, 55 °C application10 kWHP Keymark 011-1W0584
“Prated 10 kW 10 kW”
Rated heat output (Prated)warmer climate, 55 °C application9.8 kWHP Keymark 011-1W0584
“Prated 10.6 kW 9.8 kW”
Refrigerant charge—1.7 kgHP Keymark 011-1W0584
“Mass of Refrigerant 1,700 kg”
SCOPaverage climate, 35 °C application4.73 HP Keymark 011-1W0584
“SCOP 4.73 3.6”
SCOPcolder climate, 35 °C application4.34 HP Keymark 011-1W0584
“SCOP 4.34 3.29”
SCOPwarmer climate, 35 °C application6.14 HP Keymark 011-1W0584
“SCOP 6.14 4.27”
SCOPaverage climate, 55 °C application3.6 HP Keymark 011-1W0584
“SCOP 4.73 3.6”
SCOPcolder climate, 55 °C application3.29 HP Keymark 011-1W0584
“SCOP 4.34 3.29”
SCOPwarmer climate, 55 °C application4.27 HP Keymark 011-1W0584
“SCOP 6.14 4.27”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0584
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0584
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0584
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0584
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0584
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0584
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0584
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0584
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0584
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0584
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0584
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0584
“TOL 2 °C 2 °C”

Open questions