Buderus Logatherm WLW186i-12 AR E

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Logatherm WLW MB AR

Machine-readable: https://bedandbot.it/p/buderus-logatherm-wlw186i-12-ar-e.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application184 %HP Keymark 011-1W0584
“η s 184 % 137 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application167 %HP Keymark 011-1W0584
“η s 167 % 128 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application235 %HP Keymark 011-1W0584
“η s 235 % 170 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application137 %HP Keymark 011-1W0584
“η s 184 % 137 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application128 %HP Keymark 011-1W0584
“η s 167 % 128 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application170 %HP Keymark 011-1W0584
“η s 235 % 170 %”
Rated heat output (Prated)average climate, 35 °C application12.2 kWHP Keymark 011-1W0584
“Prated 12.2 kW 12 kW”
Rated heat output (Prated)colder climate, 35 °C application12 kWHP Keymark 011-1W0584
“Prated 12 kW 12 kW”
Rated heat output (Prated)warmer climate, 35 °C application12.6 kWHP Keymark 011-1W0584
“Prated 12.6 kW 12.4 kW”
Rated heat output (Prated)average climate, 55 °C application12 kWHP Keymark 011-1W0584
“Prated 12.2 kW 12 kW”
Rated heat output (Prated)colder climate, 55 °C application12 kWHP Keymark 011-1W0584
“Prated 12 kW 12 kW”
Rated heat output (Prated)warmer climate, 55 °C application12.4 kWHP Keymark 011-1W0584
“Prated 12.6 kW 12.4 kW”
Refrigerant charge—1.7 kgHP Keymark 011-1W0584
“Mass of Refrigerant 1,700 kg”
SCOPaverage climate, 35 °C application4.66 HP Keymark 011-1W0584
“SCOP 4.66 3.51”
SCOPcolder climate, 35 °C application4.24 HP Keymark 011-1W0584
“SCOP 4.24 3.27”
SCOPwarmer climate, 35 °C application5.95 HP Keymark 011-1W0584
“SCOP 5.95 4.32”
SCOPaverage climate, 55 °C application3.51 HP Keymark 011-1W0584
“SCOP 4.66 3.51”
SCOPcolder climate, 55 °C application3.27 HP Keymark 011-1W0584
“SCOP 4.24 3.27”
SCOPwarmer climate, 55 °C application4.32 HP Keymark 011-1W0584
“SCOP 5.95 4.32”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0584
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0584
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0584
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0584
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0584
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0584
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0584
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0584
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0584
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0584
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0584
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0584
“TOL 2 °C 2 °C”

Open questions