 "schema_version": 0,
 "id": "bb:product:buderus-logatherm-wlw186i-4-ar-tp70-w",
 "url": "https://bedandbot.it/p/buderus-logatherm-wlw186i-4-ar-tp70-w/",
 "json": "https://bedandbot.it/p/buderus-logatherm-wlw186i-4-ar-tp70-w.json",
 "manufacturer": "Buderus",
 "model_family": "Logatherm WLW MB AR",
 "model_code": "Logatherm WLW186i-4 AR TP70 W",
 "unit_type": "air-to-water monobloc",
 "refrigerant": "R290",
 "power_supply": "3x400V 50Hz",
 "values": [
  {
   "id": "bb:value:3756",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 179.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "η s 179 % 128 %",
    "location": "model Logatherm WLW186i-4 AR TP70 W, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3746",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 154.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "η s 154 % 105 %",
    "location": "model Logatherm WLW186i-4 AR TP70 W, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3736",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 209.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "η s 209 % 142 %",
    "location": "model Logatherm WLW186i-4 AR TP70 W, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3757",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 128.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "η s 179 % 128 %",
    "location": "model Logatherm WLW186i-4 AR TP70 W, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3747",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 105.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "η s 154 % 105 %",
    "location": "model Logatherm WLW186i-4 AR TP70 W, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3737",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 142.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "η s 209 % 142 %",
    "location": "model Logatherm WLW186i-4 AR TP70 W, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3758",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 4.4,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Prated 4.4 kW 4 kW",
    "location": "model Logatherm WLW186i-4 AR TP70 W, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3748",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 3.8,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Prated 3.8 kW 3.2 kW",
    "location": "model Logatherm WLW186i-4 AR TP70 W, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3738",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 4.3,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Prated 4.3 kW 3.8 kW",
    "location": "model Logatherm WLW186i-4 AR TP70 W, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3759",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 4.0,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Prated 4.4 kW 4 kW",
    "location": "model Logatherm WLW186i-4 AR TP70 W, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3749",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 3.2,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Prated 3.8 kW 3.2 kW",
    "location": "model Logatherm WLW186i-4 AR TP70 W, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3739",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 3.8,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Prated 4.3 kW 3.8 kW",
    "location": "model Logatherm WLW186i-4 AR TP70 W, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3766",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 0.95,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Mass of Refrigerant 0,950 kg",
    "location": "subtype Buderus Logatherm WLW MB-4/5/7 AR, general data"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3760",
   "property": "scop",
   "label": "SCOP",
   "value": 4.55,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "SCOP 4.55 3.27",
    "location": "model Logatherm WLW186i-4 AR TP70 W, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3750",
   "property": "scop",
   "label": "SCOP",
   "value": 3.93,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "SCOP 3.93 2.71",
    "location": "model Logatherm WLW186i-4 AR TP70 W, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3740",
   "property": "scop",
   "label": "SCOP",
   "value": 5.3,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "SCOP 5.30 3.62",
    "location": "model Logatherm WLW186i-4 AR TP70 W, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3761",
   "property": "scop",
   "label": "SCOP",
   "value": 3.27,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "SCOP 4.55 3.27",
    "location": "model Logatherm WLW186i-4 AR TP70 W, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3751",
   "property": "scop",
   "label": "SCOP",
   "value": 2.71,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "SCOP 3.93 2.71",
    "location": "model Logatherm WLW186i-4 AR TP70 W, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3741",
   "property": "scop",
   "label": "SCOP",
   "value": 3.62,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "SCOP 5.30 3.62",
    "location": "model Logatherm WLW186i-4 AR TP70 W, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3762",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -7.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Tbiv -7 °C -7 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3752",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3742",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3763",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -7.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Tbiv -7 °C -7 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3753",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3743",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3764",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3754",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3744",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "TOL 2 °C 2 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3765",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3755",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:3745",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=4802&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=f962e8be5892bf24158c3efa63f491c2",
    "reference": "011-1W0582",
    "document_date": "2023-03-30",
    "retrieved": "2026-10-03T19:38:12+00:00",
    "quote": "TOL 2 °C 2 °C",
    "location": "model Logatherm WLW186i-4 AR TP70 W, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  }
 ],
 "conflicts": [],
 "open_questions": [
  {
   "id": "q:buderus-logatherm-wlw186i-4-ar-tp70-w:cop-a7w35",
   "question": "We have no manufacturer-stated heating capacity and COP at A7/W35 (EN 14511) for this unit. If you know an official datasheet or manual from the manufacturer that states them, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:buderus-logatherm-wlw186i-4-ar-tp70-w:cop-a7w35",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  },
  {
   "id": "q:buderus-logatherm-wlw186i-4-ar-tp70-w:max-flow-temperature",
   "question": "We have no manufacturer-stated maximum flow temperature for this unit (and the outdoor temperature down to which it is reached). If you know an official document that states it, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:buderus-logatherm-wlw186i-4-ar-tp70-w:max-flow-temperature",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  }
 ]
}