Buderus Logatherm WLW186i-7 AR T180 W

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Logatherm WLW MB AR

Machine-readable: https://bedandbot.it/p/buderus-logatherm-wlw186i-7-ar-t180-w.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application179 %HP Keymark 011-1W0582
“η s 179 % 136 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application160 %HP Keymark 011-1W0582
“η s 160 % 116 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application206 %HP Keymark 011-1W0582
“η s 206 % 158 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application136 %HP Keymark 011-1W0582
“η s 179 % 136 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application116 %HP Keymark 011-1W0582
“η s 160 % 116 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application158 %HP Keymark 011-1W0582
“η s 206 % 158 %”
Rated heat output (Prated)average climate, 35 °C application6.6 kWHP Keymark 011-1W0582
“Prated 6.6 kW 6.6 kW”
Rated heat output (Prated)colder climate, 35 °C application7.3 kWHP Keymark 011-1W0582
“Prated 7.3 kW 6.6 kW”
Rated heat output (Prated)warmer climate, 35 °C application7.1 kWHP Keymark 011-1W0582
“Prated 7.1 kW 5.7 kW”
Rated heat output (Prated)average climate, 55 °C application6.6 kWHP Keymark 011-1W0582
“Prated 6.6 kW 6.6 kW”
Rated heat output (Prated)colder climate, 55 °C application6.6 kWHP Keymark 011-1W0582
“Prated 7.3 kW 6.6 kW”
Rated heat output (Prated)warmer climate, 55 °C application5.7 kWHP Keymark 011-1W0582
“Prated 7.1 kW 5.7 kW”
Refrigerant charge—0.95 kgHP Keymark 011-1W0582
“Mass of Refrigerant 0,950 kg”
SCOPaverage climate, 35 °C application4.56 HP Keymark 011-1W0582
“SCOP 4.56 3.48”
SCOPcolder climate, 35 °C application4.07 HP Keymark 011-1W0582
“SCOP 4.07 2.97”
SCOPwarmer climate, 35 °C application5.21 HP Keymark 011-1W0582
“SCOP 5.21 4.04”
SCOPaverage climate, 55 °C application3.48 HP Keymark 011-1W0582
“SCOP 4.56 3.48”
SCOPcolder climate, 55 °C application2.97 HP Keymark 011-1W0582
“SCOP 4.07 2.97”
SCOPwarmer climate, 55 °C application4.04 HP Keymark 011-1W0582
“SCOP 5.21 4.04”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0582
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0582
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0582
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0582
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0582
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0582
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0582
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0582
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0582
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0582
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0582
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0582
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.