Daikin EPSK08AW1 / EPVX10S23A(4V/9W)

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Altherma 4 H

Machine-readable: https://bedandbot.it/p/daikin-epsk08aw1-epvx10s23a-4v-9w.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application202 %HP Keymark 011-1W1097
“η s 202 % 155 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application155 %HP Keymark 011-1W1097
“η s 202 % 155 %”
Rated heat output (Prated)average climate, 35 °C application7.5 kWHP Keymark 011-1W1097
“Prated 7.50 kW 7.50 kW”
Rated heat output (Prated)average climate, 55 °C application7.5 kWHP Keymark 011-1W1097
“Prated 7.50 kW 7.50 kW”
Refrigerant charge—1 kgHP Keymark 011-1W1097
“Mass of Refrigerant 1,000 kg”
SCOPaverage climate, 35 °C application5.14 HP Keymark 011-1W1097
“SCOP 5.14 3.94”
SCOPaverage climate, 55 °C application3.94 HP Keymark 011-1W1097
“SCOP 5.14 3.94”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W1097
“Tbiv -10 °C -7 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W1097
“Tbiv -10 °C -7 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W1097
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W1097
“TOL -10 °C -10 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.