Daikin EPSK10AW1 / EPVX10SU23A4V

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Altherma 4 H

Machine-readable: https://bedandbot.it/p/daikin-epsk10aw1-epvx10su23a4v.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application203 %HP Keymark 011-1W1097
“η s 203 % 157 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application157 %HP Keymark 011-1W1097
“η s 203 % 157 %”
Rated heat output (Prated)average climate, 35 °C application8.5 kWHP Keymark 011-1W1097
“Prated 8.50 kW 8.50 kW”
Rated heat output (Prated)average climate, 55 °C application8.5 kWHP Keymark 011-1W1097
“Prated 8.50 kW 8.50 kW”
Refrigerant charge—1 kgHP Keymark 011-1W1097
“Mass of Refrigerant 1,000 kg”
SCOPaverage climate, 35 °C application5.14 HP Keymark 011-1W1097
“SCOP 5.14 4.00”
SCOPaverage climate, 55 °C application4 HP Keymark 011-1W1097
“SCOP 5.14 4.00”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W1097
“Tbiv -10 °C -7 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W1097
“Tbiv -10 °C -7 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W1097
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W1097
“TOL -10 °C -10 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.