LG HM051HFD UA41 / HN20XAHB NK1

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family Therma V R290 Monobloc

Machine-readable: https://bedandbot.it/p/lg-hm051hfd-ua41-hn20xahb-nk1.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application180 %HP Keymark 011-1W1195
“η s 180 % 140 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application140 %HP Keymark 011-1W1195
“η s 180 % 140 %”
Rated heat output (Prated)average climate, 35 °C application5.5 kWHP Keymark 011-1W1195
“Prated 5.50 kW 6.80 kW”
Rated heat output (Prated)average climate, 55 °C application6.8 kWHP Keymark 011-1W1195
“Prated 5.50 kW 6.80 kW”
Refrigerant charge—0.7 kgHP Keymark 011-1W1195
“Mass of Refrigerant 0,700 kg”
SCOPaverage climate, 35 °C application4.58 HP Keymark 011-1W1195
“SCOP 4.58 3.58”
SCOPaverage climate, 55 °C application3.58 HP Keymark 011-1W1195
“SCOP 4.58 3.58”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W1195
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W1195
“Tbiv -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W1195
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W1195
“TOL -10 °C -10 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.