LG HM091HF UB40 / HN1616HC NK0

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family Therma V R290 Monobloc

Machine-readable: https://bedandbot.it/p/lg-hm091hf-ub40-hn1616hc-nk0.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application205 %HP Keymark 011-1W0831
“η s 205 % 151 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application151 %HP Keymark 011-1W0831
“η s 205 % 151 %”
Rated heat output (Prated)average climate, 35 °C application6 kWHP Keymark 011-1W0831
“Prated 6.00 kW 7.00 kW”
Rated heat output (Prated)average climate, 55 °C application7 kWHP Keymark 011-1W0831
“Prated 6.00 kW 7.00 kW”
Refrigerant charge—0.9 kgHP Keymark 011-1W0831
“Mass of Refrigerant 0,900 kg”
SCOPaverage climate, 35 °C application5.2 HP Keymark 011-1W0831
“SCOP 5.20 3.86”
SCOPaverage climate, 55 °C application3.86 HP Keymark 011-1W0831
“SCOP 5.20 3.86”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0831
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0831
“Tbiv -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0831
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0831
“TOL -10 °C -10 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.