LG HM123HF UB60 / HN20XAHY NK1

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Therma V R290 Monobloc

Machine-readable: https://bedandbot.it/p/lg-hm123hf-ub60-hn20xahy-nk1.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application215 %HP Keymark 011-1W0689
“η s 215 % 156 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application156 %HP Keymark 011-1W0689
“η s 215 % 156 %”
Rated heat output (Prated)average climate, 35 °C application10 kWHP Keymark 011-1W0689
“Prated 10.00 kW 10.00 kW”
Rated heat output (Prated)average climate, 55 °C application10 kWHP Keymark 011-1W0689
“Prated 10.00 kW 10.00 kW”
Refrigerant charge—1.2 kgHP Keymark 011-1W0689
“Mass of Refrigerant 1,200 kg”
SCOPaverage climate, 35 °C application5.45 HP Keymark 011-1W0689
“SCOP 5.45 3.97”
SCOPaverage climate, 55 °C application3.97 HP Keymark 011-1W0689
“SCOP 5.45 3.97”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0689
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0689
“Tbiv -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0689
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0689
“TOL -10 °C -10 °C”

Open questions