LG HM143HF UB60 / HN1639HY NK0

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Therma V R290 Monobloc

Machine-readable: https://bedandbot.it/p/lg-hm143hf-ub60-hn1639hy-nk0.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application212 %HP Keymark 011-1W0689
“η s 212 % 155 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application155 %HP Keymark 011-1W0689
“η s 212 % 155 %”
Rated heat output (Prated)average climate, 35 °C application11 kWHP Keymark 011-1W0689
“Prated 11.00 kW 11.00 kW”
Rated heat output (Prated)average climate, 55 °C application11 kWHP Keymark 011-1W0689
“Prated 11.00 kW 11.00 kW”
Refrigerant charge—1.2 kgHP Keymark 011-1W0689
“Mass of Refrigerant 1,200 kg”
SCOPaverage climate, 35 °C application5.38 HP Keymark 011-1W0689
“SCOP 5.38 3.96”
SCOPaverage climate, 55 °C application3.96 HP Keymark 011-1W0689
“SCOP 5.38 3.96”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0689
“Tbiv -7 °C -10 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0689
“Tbiv -7 °C -10 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0689
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0689
“TOL -10 °C -10 °C”

Open questions