{
 "schema_version": 0,
 "id": "bb:product:mitsubishi-electric-puz-wz50vaa-bs-erpt20x-m-e",
 "url": "https://bedandbot.it/p/mitsubishi-electric-puz-wz50vaa-bs-erpt20x-m-e/",
 "json": "https://bedandbot.it/p/mitsubishi-electric-puz-wz50vaa-bs-erpt20x-m-e.json",
 "manufacturer": "Mitsubishi Electric",
 "model_family": "Ecodan Packaged R290",
 "model_code": "PUZ-WZ50VAA(-BS) + ERPT20X-*M*E",
 "unit_type": "air-to-water monobloc",
 "refrigerant": "R290",
 "power_supply": "1x230V 50Hz",
 "values": [
  {
   "id": "bb:value:27146",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 182.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "η s 182 % 138 %",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27136",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 244.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "η s 244 % 165 %",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27147",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 138.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "η s 182 % 138 %",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27137",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 165.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "η s 244 % 165 %",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27148",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.0,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "Prated 5 kW 5 kW",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27138",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.0,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "Prated 5 kW 5 kW",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27149",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.0,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "Prated 5 kW 5 kW",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27139",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.0,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "Prated 5 kW 5 kW",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27156",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 0.6,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "Mass of Refrigerant 0,600 kg",
    "location": "subtype Ecodan Power Inverter 5/6-200E Packaged R290, general data"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27150",
   "property": "scop",
   "label": "SCOP",
   "value": 4.62,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "SCOP 4.62 3.53",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27140",
   "property": "scop",
   "label": "SCOP",
   "value": 6.17,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "SCOP 6.17 4.21",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27151",
   "property": "scop",
   "label": "SCOP",
   "value": 3.53,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "SCOP 4.62 3.53",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27141",
   "property": "scop",
   "label": "SCOP",
   "value": 4.21,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "SCOP 6.17 4.21",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27152",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -7.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "Tbiv -7 °C -7 °C",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27142",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27153",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -7.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "Tbiv -7 °C -7 °C",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27143",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27154",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -25.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "TOL -25 °C -25 °C",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27144",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -25.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "TOL -25 °C -25 °C",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27155",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -25.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "TOL -25 °C -25 °C",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  },
  {
   "id": "bb:value:27145",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -25.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=6773&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=c6767cebc4013f4b4f7be8283f7adbcb",
    "reference": "037-0135-23",
    "document_date": "2023-08-31",
    "retrieved": "2026-10-04T03:15:09+00:00",
    "quote": "TOL -25 °C -25 °C",
    "location": "model PUZ-WZ50VAA(-BS) + ERPT20X-*M*E, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-04T05:26:41+00:00"
  }
 ],
 "conflicts": [],
 "open_questions": [
  {
   "id": "q:mitsubishi-electric-puz-wz50vaa-bs-erpt20x-m-e:cop-a7w35",
   "question": "We have no manufacturer-stated heating capacity and COP at A7/W35 (EN 14511) for this unit. If you know an official datasheet or manual from the manufacturer that states them, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:mitsubishi-electric-puz-wz50vaa-bs-erpt20x-m-e:cop-a7w35",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  },
  {
   "id": "q:mitsubishi-electric-puz-wz50vaa-bs-erpt20x-m-e:max-flow-temperature",
   "question": "We have no manufacturer-stated maximum flow temperature for this unit (and the outdoor temperature down to which it is reached). If you know an official document that states it, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:mitsubishi-electric-puz-wz50vaa-bs-erpt20x-m-e:max-flow-temperature",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  }
 ]
}