PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application182 %HP Keymark 037-0135-23
“η s 182 % 138 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application244 %HP Keymark 037-0135-23
“η s 244 % 165 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application138 %HP Keymark 037-0135-23
“η s 182 % 138 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application165 %HP Keymark 037-0135-23
“η s 244 % 165 %”
Rated heat output (Prated)average climate, 35 °C application5 kWHP Keymark 037-0135-23
“Prated 5 kW 5 kW”
Rated heat output (Prated)warmer climate, 35 °C application5 kWHP Keymark 037-0135-23
“Prated 5 kW 5 kW”
Rated heat output (Prated)average climate, 55 °C application5 kWHP Keymark 037-0135-23
“Prated 5 kW 5 kW”
Rated heat output (Prated)warmer climate, 55 °C application5 kWHP Keymark 037-0135-23
“Prated 5 kW 5 kW”
Refrigerant charge—0.6 kgHP Keymark 037-0135-23
“Mass of Refrigerant 0,600 kg”
SCOPaverage climate, 35 °C application4.62 HP Keymark 037-0135-23
“SCOP 4.62 3.53”
SCOPwarmer climate, 35 °C application6.17 HP Keymark 037-0135-23
“SCOP 6.17 4.21”
SCOPaverage climate, 55 °C application3.53 HP Keymark 037-0135-23
“SCOP 4.62 3.53”
SCOPwarmer climate, 55 °C application4.21 HP Keymark 037-0135-23
“SCOP 6.17 4.21”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 037-0135-23
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 037-0135-23
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 037-0135-23
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 037-0135-23
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-25 °CHP Keymark 037-0135-23
“TOL -25 °C -25 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application-25 °CHP Keymark 037-0135-23
“TOL -25 °C -25 °C”
Operation limit temperature (TOL)average climate, 55 °C application-25 °CHP Keymark 037-0135-23
“TOL -25 °C -25 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application-25 °CHP Keymark 037-0135-23
“TOL -25 °C -25 °C”

Open questions