 "schema_version": 0,
 "id": "bb:product:nibe-s2125-12-1x230v",
 "url": "https://bedandbot.it/p/nibe-s2125-12-1x230v/",
 "json": "https://bedandbot.it/p/nibe-s2125-12-1x230v.json",
 "manufacturer": "NIBE",
 "model_family": "S2125",
 "model_code": "S2125-12 1x230V",
 "unit_type": "air-to-water monobloc",
 "refrigerant": "R290",
 "power_supply": "1x230V 50Hz",
 "values": [
  {
   "id": "bb:value:2138",
   "property": "cooling_capacity",
   "label": "Cooling capacity",
   "value": 8.68,
   "unit": "kW",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W18"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2130",
   "property": "cooling_capacity",
   "label": "Cooling capacity",
   "value": 6.69,
   "unit": "kW",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W7"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2085",
   "property": "cop",
   "label": "COP",
   "value": 2.65,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2097",
   "property": "cop",
   "label": "COP",
   "value": 4.32,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A2/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2109",
   "property": "cop",
   "label": "COP",
   "value": 5.24,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2121",
   "property": "cop",
   "label": "COP",
   "value": 3.94,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W45"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2139",
   "property": "eer",
   "label": "EER",
   "value": 3.34,
   "unit": "-",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W18"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2131",
   "property": "eer",
   "label": "EER",
   "value": 2.77,
   "unit": "-",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W7"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2198",
   "property": "energy_class",
   "label": "Energy class",
   "value": "A+++",
   "unit": "classe",
   "conditions": {
    "application_c": 35
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2199",
   "property": "energy_class",
   "label": "Energy class",
   "value": "A+++",
   "unit": "classe",
   "conditions": {
    "application_c": 55
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:137",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 195.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "η s 195 % 150 %",
    "location": "model S2125-12 1x230V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:127",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 163.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "η s 163 % 131 %",
    "location": "model S2125-12 1x230V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:138",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 150.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "η s 195 % 150 %",
    "location": "model S2125-12 1x230V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:128",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 131.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "η s 163 % 131 %",
    "location": "model S2125-12 1x230V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2145",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 8.34,
   "unit": "kW",
   "conditions": {
    "load": "max",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Maximum capacity, heating, at A-7W35 kW 5.52 8.34 11.42 13.64",
    "location": "page 50, technical data, column S2125-12 1x230V, without defrosting"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2083",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 7.23,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2095",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 3.67,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A2/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2107",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 3.67,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2119",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 3.35,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W45"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2225",
   "property": "max_flow_temperature",
   "label": "Maximum flow temperature",
   "value": 75.0,
   "unit": "°C",
   "conditions": {},
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min/max supply temperature for heating medium (HM) °C 25 / 75",
    "location": "page 50, technical data, column S2125-12 1x230V, continuous operation"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2219",
   "property": "operating_range_cooling",
   "label": "Operating range, cooling (outdoor air)",
   "value": 43.0,
   "unit": "°C",
   "conditions": {
    "limit": "max"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2218",
   "property": "operating_range_cooling",
   "label": "Operating range, cooling (outdoor air)",
   "value": 15.0,
   "unit": "°C",
   "conditions": {
    "limit": "min"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2211",
   "property": "operating_range_heating",
   "label": "Operating range, heating (outdoor air)",
   "value": 38.0,
   "unit": "°C",
   "conditions": {
    "limit": "max"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2210",
   "property": "operating_range_heating",
   "label": "Operating range, heating (outdoor air)",
   "value": -25.0,
   "unit": "°C",
   "conditions": {
    "limit": "min"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2084",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 2.73,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2096",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 0.85,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A2/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2108",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 0.7,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2120",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 0.85,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W45"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:139",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 6.8,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Prated 6.80 kW 7.60 kW",
    "location": "model S2125-12 1x230V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2150",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 6.8,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:129",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.4,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Prated 8.40 kW 8.40 kW",
    "location": "model S2125-12 1x230V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2158",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.4,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2166",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.0,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:140",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.6,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Prated 6.80 kW 7.60 kW",
    "location": "model S2125-12 1x230V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2151",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.6,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:130",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.4,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Prated 8.40 kW 8.40 kW",
    "location": "model S2125-12 1x230V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2159",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.4,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2167",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.45,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:147",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 0.8,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Mass of Refrigerant 0,800 kg",
    "location": "subtype S2125-12, general data"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2205",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 0.8,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Filling amount kg 0.8 0.8 1.15 1.15",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:141",
   "property": "scop",
   "label": "SCOP",
   "value": 4.96,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "SCOP 4.96 3.83",
    "location": "model S2125-12 1x230V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2174",
   "property": "scop",
   "label": "SCOP",
   "value": 5.0,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:131",
   "property": "scop",
   "label": "SCOP",
   "value": 4.15,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "SCOP 4.15 3.35",
    "location": "model S2125-12 1x230V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2182",
   "property": "scop",
   "label": "SCOP",
   "value": 4.2,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2190",
   "property": "scop",
   "label": "SCOP",
   "value": 6.3,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:142",
   "property": "scop",
   "label": "SCOP",
   "value": 3.83,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "SCOP 4.96 3.83",
    "location": "model S2125-12 1x230V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2175",
   "property": "scop",
   "label": "SCOP",
   "value": 3.8,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:132",
   "property": "scop",
   "label": "SCOP",
   "value": 3.35,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "SCOP 4.15 3.35",
    "location": "model S2125-12 1x230V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2183",
   "property": "scop",
   "label": "SCOP",
   "value": 3.4,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2191",
   "property": "scop",
   "label": "SCOP",
   "value": 4.6,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78",
    "location": "page 50, technical data, column S2125-12 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:143",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Tbiv -10 °C -10 °C",
    "location": "model S2125-12 1x230V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:133",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model S2125-12 1x230V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:144",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Tbiv -10 °C -10 °C",
    "location": "model S2125-12 1x230V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:134",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model S2125-12 1x230V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:145",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model S2125-12 1x230V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:135",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model S2125-12 1x230V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:146",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model S2125-12 1x230V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:136",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model S2125-12 1x230V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  }
 ],
 "conflicts": [],
 "open_questions": []
}