 "schema_version": 0,
 "id": "bb:product:nibe-s2125-12-3x400v",
 "url": "https://bedandbot.it/p/nibe-s2125-12-3x400v/",
 "json": "https://bedandbot.it/p/nibe-s2125-12-3x400v.json",
 "manufacturer": "NIBE",
 "model_family": "S2125",
 "model_code": "S2125-12 3x400V",
 "unit_type": "air-to-water monobloc",
 "refrigerant": "R290",
 "power_supply": "3x400V 50Hz",
 "values": [
  {
   "id": "bb:value:2286",
   "property": "cooling_capacity",
   "label": "Cooling capacity",
   "value": 8.68,
   "unit": "kW",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W18"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2278",
   "property": "cooling_capacity",
   "label": "Cooling capacity",
   "value": 6.69,
   "unit": "kW",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W7"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2233",
   "property": "cop",
   "label": "COP",
   "value": 2.65,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2245",
   "property": "cop",
   "label": "COP",
   "value": 4.32,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A2/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2257",
   "property": "cop",
   "label": "COP",
   "value": 5.24,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2269",
   "property": "cop",
   "label": "COP",
   "value": 3.94,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W45"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2287",
   "property": "eer",
   "label": "EER",
   "value": 3.34,
   "unit": "-",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W18"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2279",
   "property": "eer",
   "label": "EER",
   "value": 2.77,
   "unit": "-",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W7"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2346",
   "property": "energy_class",
   "label": "Energy class",
   "value": "A+++",
   "unit": "classe",
   "conditions": {
    "application_c": 35
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2347",
   "property": "energy_class",
   "label": "Energy class",
   "value": "A+++",
   "unit": "classe",
   "conditions": {
    "application_c": 55
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:116",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 195.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "η s 195 % 150 %",
    "location": "model S2125-12 3x400V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:106",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 163.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "η s 163 % 131 %",
    "location": "model S2125-12 3x400V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:117",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 150.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "η s 195 % 150 %",
    "location": "model S2125-12 3x400V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:107",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 131.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "η s 163 % 131 %",
    "location": "model S2125-12 3x400V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2293",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 8.34,
   "unit": "kW",
   "conditions": {
    "load": "max",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Maximum capacity, heating, at A-7W35 kW 5.52 8.34 11.42 13.64",
    "location": "page 52, technical data, column S2125-12 3x400V, without defrosting"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2231",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 7.23,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2243",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 3.67,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A2/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2255",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 3.67,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2267",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 3.35,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W45"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2367",
   "property": "operating_range_cooling",
   "label": "Operating range, cooling (outdoor air)",
   "value": 43.0,
   "unit": "°C",
   "conditions": {
    "limit": "max"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2366",
   "property": "operating_range_cooling",
   "label": "Operating range, cooling (outdoor air)",
   "value": 15.0,
   "unit": "°C",
   "conditions": {
    "limit": "min"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2359",
   "property": "operating_range_heating",
   "label": "Operating range, heating (outdoor air)",
   "value": 38.0,
   "unit": "°C",
   "conditions": {
    "limit": "max"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2358",
   "property": "operating_range_heating",
   "label": "Operating range, heating (outdoor air)",
   "value": -25.0,
   "unit": "°C",
   "conditions": {
    "limit": "min"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2232",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 2.73,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2244",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 0.85,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A2/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2256",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 0.7,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2268",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 0.85,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W45"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:118",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 6.8,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Prated 6.80 kW 7.60 kW",
    "location": "model S2125-12 3x400V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2298",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 6.8,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:108",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.4,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Prated 8.40 kW 8.40 kW",
    "location": "model S2125-12 3x400V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2306",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.4,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2314",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.0,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:119",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.6,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Prated 6.80 kW 7.60 kW",
    "location": "model S2125-12 3x400V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2299",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.6,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:109",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.4,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Prated 8.40 kW 8.40 kW",
    "location": "model S2125-12 3x400V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2307",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 8.4,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2315",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 7.45,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:126",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 0.8,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Mass of Refrigerant 0,800 kg",
    "location": "subtype S2125-12, general data"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2353",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 0.8,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Filling amount kg 0.8 0.8 1.15 1.15",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:120",
   "property": "scop",
   "label": "SCOP",
   "value": 4.96,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "SCOP 4.96 3.83",
    "location": "model S2125-12 3x400V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2322",
   "property": "scop",
   "label": "SCOP",
   "value": 5.0,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:110",
   "property": "scop",
   "label": "SCOP",
   "value": 4.15,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "SCOP 4.15 3.35",
    "location": "model S2125-12 3x400V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2330",
   "property": "scop",
   "label": "SCOP",
   "value": 4.2,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2338",
   "property": "scop",
   "label": "SCOP",
   "value": 6.3,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:121",
   "property": "scop",
   "label": "SCOP",
   "value": 3.83,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "SCOP 4.96 3.83",
    "location": "model S2125-12 3x400V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2323",
   "property": "scop",
   "label": "SCOP",
   "value": 3.8,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:111",
   "property": "scop",
   "label": "SCOP",
   "value": 3.35,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "SCOP 4.15 3.35",
    "location": "model S2125-12 3x400V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2331",
   "property": "scop",
   "label": "SCOP",
   "value": 3.4,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2339",
   "property": "scop",
   "label": "SCOP",
   "value": 4.6,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78",
    "location": "page 52, technical data, column S2125-12 3x400V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:122",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Tbiv -10 °C -10 °C",
    "location": "model S2125-12 3x400V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:112",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model S2125-12 3x400V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:123",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Tbiv -10 °C -10 °C",
    "location": "model S2125-12 3x400V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:113",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model S2125-12 3x400V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:124",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model S2125-12 3x400V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:114",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model S2125-12 3x400V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:125",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model S2125-12 3x400V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:115",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2772&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=d90d147e2765330b7fa0ff55c291cd55",
    "reference": "012-C700115",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:30:39+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model S2125-12 3x400V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  }
 ],
 "conflicts": [],
 "open_questions": [
  {
   "id": "q:nibe-s2125-12-3x400v:max-flow-temperature",
   "question": "We have no manufacturer-stated maximum flow temperature for this unit (and the outdoor temperature down to which it is reached). If you know an official document that states it, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:nibe-s2125-12-3x400v:max-flow-temperature",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },