PropertyConditionsValueSource
Cooling capacityA35/W18, non_dichiarato load13.62 kWNIBE
“Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93”
Cooling capacityA35/W7, non_dichiarato load9.74 kWNIBE
“Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08”
COPA-7/W35, partial load2.77 NIBE
“Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64”
COPA2/W35, partial load4.66 NIBE
“Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63”
COPA7/W35, partial load5.55 NIBE
“7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55”
COPA7/W45, partial load4.12 NIBE
“7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12”
EERA35/W18, non_dichiarato load3.93 NIBE
“Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93”
EERA35/W7, non_dichiarato load3.08 NIBE
“Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08”
Energy class35 °C applicationA+++ classeNIBE
“The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++”
Energy class55 °C applicationA+++ classeNIBE
“The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++”
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application210 %HP Keymark 012-C700272
“η s 210 % 160 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application176 %HP Keymark 012-C700272
“η s 176 % 141 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application160 %HP Keymark 012-C700272
“η s 210 % 160 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application141 %HP Keymark 012-C700272
“η s 176 % 141 %”
Heating capacityA-7/W35, max load11.42 kWNIBE
“Maximum capacity, heating, at A-7W35 kW 5.52 8.34 11.42 13.64”
Heating capacityA-7/W35, partial load10.31 kWNIBE
“Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64”
Heating capacityA2/W35, partial load6.58 kWNIBE
“Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63”
Heating capacityA7/W35, partial load5.1 kWNIBE
“7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55”
Heating capacityA7/W45, partial load4.85 kWNIBE
“7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12”
Operating range, cooling (outdoor air)—45 °CNIBE
“Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45”
Operating range, cooling (outdoor air)—15 °CNIBE
“Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45”
Operating range, heating (outdoor air)—40 °CNIBE
“Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40”
Operating range, heating (outdoor air)—-25 °CNIBE
“Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40”
Power input (heating)A-7/W35, partial load3.72 kWNIBE
“Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64”
Power input (heating)A2/W35, partial load1.41 kWNIBE
“Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63”
Power input (heating)A7/W35, partial load0.92 kWNIBE
“7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55”
Power input (heating)A7/W45, partial load1.18 kWNIBE
“7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12”
Rated heat output (Prated)average climate, 35 °C application11 kWHP Keymark 012-C700272
“Prated 11.00 kW 11.00 kW”
Rated heat output (Prated)average climate, 35 °C application11 kWNIBE
“Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00”
Rated heat output (Prated)colder climate, 35 °C application13 kWHP Keymark 012-C700272
“Prated 13.00 kW 14.00 kW”
Rated heat output (Prated)colder climate, 35 °C application13 kWNIBE
“Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00”
Rated heat output (Prated)warmer climate, 35 °C application13 kWNIBE
“Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00”
Rated heat output (Prated)average climate, 55 °C application11 kWHP Keymark 012-C700272
“Prated 11.00 kW 11.00 kW”
Rated heat output (Prated)average climate, 55 °C application11 kWNIBE
“Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00”
Rated heat output (Prated)colder climate, 55 °C application14 kWHP Keymark 012-C700272
“Prated 13.00 kW 14.00 kW”
Rated heat output (Prated)colder climate, 55 °C application14 kWNIBE
“Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00”
Rated heat output (Prated)warmer climate, 55 °C application13 kWNIBE
“Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00”
Refrigerant charge—1.15 kgHP Keymark 012-C700272
“Mass of Refrigerant 1,150 kg”
Refrigerant charge—1.15 kgNIBE
“Filling amount kg 0.8 0.8 1.15 1.15”
SCOPaverage climate, 35 °C application5.34 HP Keymark 012-C700272
“SCOP 5.34 4.08”
SCOPaverage climate, 35 °C application5.33 NIBE
“SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08”
SCOPcolder climate, 35 °C application4.48 HP Keymark 012-C700272
“SCOP 4.48 3.59”
SCOPcolder climate, 35 °C application4.47 NIBE
“SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69”
SCOPwarmer climate, 35 °C application5.98 NIBE
“SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78”
SCOPaverage climate, 55 °C application4.08 HP Keymark 012-C700272
“SCOP 5.34 4.08”
SCOPaverage climate, 55 °C application4.08 NIBE
“SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08”
SCOPcolder climate, 55 °C application3.59 HP Keymark 012-C700272
“SCOP 4.48 3.59”
SCOPcolder climate, 55 °C application3.59 NIBE
“SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69”
SCOPwarmer climate, 55 °C application4.79 NIBE
“SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 012-C700272
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-12 °CHP Keymark 012-C700272
“Tbiv -12 °C -11 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 012-C700272
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-11 °CHP Keymark 012-C700272
“Tbiv -12 °C -11 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 012-C700272
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 012-C700272
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 012-C700272
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 012-C700272
“TOL -22 °C -22 °C”