NIBE S2125-20 1X230V
air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family S2125
Machine-readable: https://bedandbot.it/p/nibe-s2125-20-1x230v.json
| Property | Conditions | Value | Source |
|---|---|---|---|
| Cooling capacity | A35/W18, non_dichiarato load | 13.62 kW | NIBE “Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93” |
| Cooling capacity | A35/W7, non_dichiarato load | 9.74 kW | NIBE “Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08” |
| COP | A-7/W35, partial load | 2.64 | NIBE “Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64” |
| COP | A2/W35, partial load | 4.63 | NIBE “Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63” |
| COP | A7/W35, partial load | 5.55 | NIBE “7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55” |
| COP | A7/W45, partial load | 4.12 | NIBE “7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12” |
| EER | A35/W18, non_dichiarato load | 3.93 | NIBE “Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93” |
| EER | A35/W7, non_dichiarato load | 3.08 | NIBE “Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08” |
| Energy class | 35 °C application | A+++ classe | NIBE “The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++” |
| Energy class | 55 °C application | A+++ classe | NIBE “The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++” |
| Seasonal space heating energy efficiency (ηs) | average climate, 35 °C application | 209 % | HP Keymark 012-C700273 “η s 209 % 160 %” |
| Seasonal space heating energy efficiency (ηs) | colder climate, 35 °C application | 181 % | HP Keymark 012-C700273 “η s 181 % 144 %” |
| Seasonal space heating energy efficiency (ηs) | average climate, 55 °C application | 160 % | HP Keymark 012-C700273 “η s 209 % 160 %” |
| Seasonal space heating energy efficiency (ηs) | colder climate, 55 °C application | 144 % | HP Keymark 012-C700273 “η s 181 % 144 %” |
| Heating capacity | A-7/W35, max load | 13.64 kW | NIBE “Maximum capacity, heating, at A-7W35 kW 5.52 8.34 11.42 13.64” |
| Heating capacity | A-7/W35, partial load | 12.03 kW | NIBE “Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64” |
| Heating capacity | A2/W35, partial load | 7.38 kW | NIBE “Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63” |
| Heating capacity | A7/W35, partial load | 5.1 kW | NIBE “7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55” |
| Heating capacity | A7/W45, partial load | 4.85 kW | NIBE “7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12” |
| Maximum flow temperature | — | 75 °C | NIBE “Min/max supply temperature for heating medium (HM) °C 25 / 75” |
| Operating range, cooling (outdoor air) | — | 45 °C | NIBE “Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45” |
| Operating range, cooling (outdoor air) | — | 15 °C | NIBE “Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45” |
| Operating range, heating (outdoor air) | — | 40 °C | NIBE “Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40” |
| Operating range, heating (outdoor air) | — | -25 °C | NIBE “Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40” |
| Power input (heating) | A-7/W35, partial load | 4.56 kW | NIBE “Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64” |
| Power input (heating) | A2/W35, partial load | 1.59 kW | NIBE “Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63” |
| Power input (heating) | A7/W35, partial load | 0.92 kW | NIBE “7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55” |
| Power input (heating) | A7/W45, partial load | 1.18 kW | NIBE “7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12” |
| Rated heat output (Prated) | average climate, 35 °C application | 11 kW | HP Keymark 012-C700273 “Prated 11.00 kW 11.00 kW” |
| Rated heat output (Prated) | average climate, 35 °C application | 11 kW | NIBE “Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00” |
| Rated heat output (Prated) | colder climate, 35 °C application | 13 kW | HP Keymark 012-C700273 “Prated 13.00 kW 14.00 kW” |
| Rated heat output (Prated) | colder climate, 35 °C application | 13 kW | NIBE “Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00” |
| Rated heat output (Prated) | warmer climate, 35 °C application | 13 kW | NIBE “Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00” |
| Rated heat output (Prated) | average climate, 55 °C application | 11 kW | HP Keymark 012-C700273 “Prated 11.00 kW 11.00 kW” |
| Rated heat output (Prated) | average climate, 55 °C application | 11 kW | NIBE “Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00” |
| Rated heat output (Prated) | colder climate, 55 °C application | 14 kW | HP Keymark 012-C700273 “Prated 13.00 kW 14.00 kW” |
| Rated heat output (Prated) | colder climate, 55 °C application | 14 kW | NIBE “Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00” |
| Rated heat output (Prated) | warmer climate, 55 °C application | 13 kW | NIBE “Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00” |
| Refrigerant charge | — | 1.15 kg | HP Keymark 012-C700273 “Mass of Refrigerant 1,150 kg” |
| Refrigerant charge | — | 1.15 kg | NIBE “Filling amount kg 0.8 0.8 1.15 1.15” |
| SCOP | average climate, 35 °C application | 5.3 | HP Keymark 012-C700273 “SCOP 5.30 4.08” |
| SCOP | average climate, 35 °C application | 5.3 | NIBE “SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08” |
| SCOP | colder climate, 35 °C application | 4.6 | HP Keymark 012-C700273 “SCOP 4.60 3.69” |
| SCOP | colder climate, 35 °C application | 4.6 | NIBE “SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69” |
| SCOP | warmer climate, 35 °C application | 6.29 | NIBE “SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78” |
| SCOP | average climate, 55 °C application | 4.08 | HP Keymark 012-C700273 “SCOP 5.30 4.08” |
| SCOP | average climate, 55 °C application | 4.08 | NIBE “SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08” |
| SCOP | colder climate, 55 °C application | 3.69 | HP Keymark 012-C700273 “SCOP 4.60 3.69” |
| SCOP | colder climate, 55 °C application | 3.69 | NIBE “SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69” |
| SCOP | warmer climate, 55 °C application | 4.78 | NIBE “SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78” |
| Bivalent temperature (Tbiv) | average climate, 35 °C application | -10 °C | HP Keymark 012-C700273 “Tbiv -10 °C -10 °C” |
| Bivalent temperature (Tbiv) | colder climate, 35 °C application | -15 °C | HP Keymark 012-C700273 “Tbiv -15 °C -15 °C” |
| Bivalent temperature (Tbiv) | average climate, 55 °C application | -10 °C | HP Keymark 012-C700273 “Tbiv -10 °C -10 °C” |
| Bivalent temperature (Tbiv) | colder climate, 55 °C application | -15 °C | HP Keymark 012-C700273 “Tbiv -15 °C -15 °C” |
| Operation limit temperature (TOL) | average climate, 35 °C application | -10 °C | HP Keymark 012-C700273 “TOL -10 °C -10 °C” |
| Operation limit temperature (TOL) | colder climate, 35 °C application | -22 °C | HP Keymark 012-C700273 “TOL -22 °C -22 °C” |
| Operation limit temperature (TOL) | average climate, 55 °C application | -10 °C | HP Keymark 012-C700273 “TOL -10 °C -10 °C” |
| Operation limit temperature (TOL) | colder climate, 55 °C application | -22 °C | HP Keymark 012-C700273 “TOL -22 °C -22 °C” |
Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.