 "schema_version": 0,
 "id": "bb:product:nibe-s2125-8-1x230v",
 "url": "https://bedandbot.it/p/nibe-s2125-8-1x230v/",
 "json": "https://bedandbot.it/p/nibe-s2125-8-1x230v.json",
 "manufacturer": "NIBE",
 "model_family": "S2125",
 "model_code": "S2125-8 1x230V",
 "unit_type": "air-to-water monobloc",
 "refrigerant": "R290",
 "power_supply": "1x230V 50Hz",
 "values": [
  {
   "id": "bb:value:2136",
   "property": "cooling_capacity",
   "label": "Cooling capacity",
   "value": 8.68,
   "unit": "kW",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W18"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2128",
   "property": "cooling_capacity",
   "label": "Cooling capacity",
   "value": 6.69,
   "unit": "kW",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W7"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2082",
   "property": "cop",
   "label": "COP",
   "value": 2.74,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2094",
   "property": "cop",
   "label": "COP",
   "value": 4.44,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A2/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2106",
   "property": "cop",
   "label": "COP",
   "value": 5.16,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2118",
   "property": "cop",
   "label": "COP",
   "value": 3.9,
   "unit": "-",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W45"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2137",
   "property": "eer",
   "label": "EER",
   "value": 3.34,
   "unit": "-",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W18"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / EER (kW/kW/-) at maximum flow 35 / 18 °C 8.68 / 2.60 / 3.34 8.68 / 2.60 / 3.34 13.62 / 3.46 / 3.93 13.62 / 3.46 / 3.93",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2129",
   "property": "eer",
   "label": "EER",
   "value": 2.77,
   "unit": "-",
   "conditions": {
    "load": "non_dichiarato",
    "test_point": "A35/W7"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Cooling 35 / 7 °C 6.69 / 2.41 / 2.77 6.69 / 2.41 / 2.77 9.74 / 3.16 / 3.08 9.74 / 3.16 / 3.08",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2196",
   "property": "energy_class",
   "label": "Energy class",
   "value": "A+++",
   "unit": "classe",
   "conditions": {
    "application_c": 35
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2197",
   "property": "energy_class",
   "label": "Energy class",
   "value": "A++",
   "unit": "classe",
   "conditions": {
    "application_c": 55
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "The product’s room heating efficiency class A+++ / A++ A+++ / A+++ A+++ / A+++ A+++ / A+++",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:179",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 196.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "η s 196 % 146 %",
    "location": "model S2125-8 1x230V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:169",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 161.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "η s 161 % 123 %",
    "location": "model S2125-8 1x230V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:180",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 146.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "η s 196 % 146 %",
    "location": "model S2125-8 1x230V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:170",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 123.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "η s 161 % 123 %",
    "location": "model S2125-8 1x230V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2144",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 5.52,
   "unit": "kW",
   "conditions": {
    "load": "max",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Maximum capacity, heating, at A-7W35 kW 5.52 8.34 11.42 13.64",
    "location": "page 50, technical data, column S2125-8 1x230V, without defrosting"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2080",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 4.72,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2092",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 3.2,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A2/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2104",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 3.15,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2116",
   "property": "heating_capacity",
   "label": "Heating capacity",
   "value": 2.97,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W45"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2224",
   "property": "max_flow_temperature",
   "label": "Maximum flow temperature",
   "value": 75.0,
   "unit": "°C",
   "conditions": {},
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min/max supply temperature for heating medium (HM) °C 25 / 75",
    "location": "page 50, technical data, column S2125-8 1x230V, continuous operation"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2217",
   "property": "operating_range_cooling",
   "label": "Operating range, cooling (outdoor air)",
   "value": 43.0,
   "unit": "°C",
   "conditions": {
    "limit": "max"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2216",
   "property": "operating_range_cooling",
   "label": "Operating range, cooling (outdoor air)",
   "value": 15.0,
   "unit": "°C",
   "conditions": {
    "limit": "min"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, cooling °C 15 / 43 15 / 43 15 / 45 15 / 45",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2209",
   "property": "operating_range_heating",
   "label": "Operating range, heating (outdoor air)",
   "value": 38.0,
   "unit": "°C",
   "conditions": {
    "limit": "max"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2208",
   "property": "operating_range_heating",
   "label": "Operating range, heating (outdoor air)",
   "value": -25.0,
   "unit": "°C",
   "conditions": {
    "limit": "min"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Min./max. air temperature, heating °C -25 / 38 -25 / 38 -25 / 40 -25 / 40",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2081",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 1.72,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A-7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Heating -7 / 35 °C 4.72 / 1.72 / 2.74 7.23 / 2.73 / 2.65 10.31 / 3.72 / 2.77 12.03 / 4.56 / 2.64",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2093",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 0.72,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A2/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Capacity / power input / COP (kW/kW/-) at nominal flow 2 / 35 °C 3.20 / 0.72 / 4.44 3.67 / 0.85 / 4.32 6.58 / 1.41 / 4.66 7.38 / 1.59 / 4.63",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2105",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 0.61,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W35"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 35 °C 3.15 / 0.61 / 5.16 3.67 / 0.70 / 5.24 5.10 / 0.92 / 5.55 5.10 / 0.92 / 5.55",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2117",
   "property": "power_input_heating",
   "label": "Power input (heating)",
   "value": 0.76,
   "unit": "kW",
   "conditions": {
    "load": "partial",
    "test_point": "A7/W45"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "7 / 45 °C 2.97 / 0.76 / 3.90 3.35 / 0.85 / 3.94 4.85 / 1.18 / 4.12 4.85 / 1.18 / 4.12",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:181",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.3,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "Prated 5.30 kW 5.30 kW",
    "location": "model S2125-8 1x230V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2148",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.33,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:171",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.4,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "Prated 5.40 kW 5.20 kW",
    "location": "model S2125-8 1x230V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2156",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.4,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2164",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.5,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:182",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.3,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "Prated 5.30 kW 5.30 kW",
    "location": "model S2125-8 1x230V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2149",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.3,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) average climate kW 5.33 / 5.30 6.80 / 7.60 11.00 / 11.00 11.00 / 11.00",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:172",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.2,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "Prated 5.40 kW 5.20 kW",
    "location": "model S2125-8 1x230V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2157",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.2,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) cold climate 35 °C / 55 °C kW 5.40 / 5.20 8.40 / 8.40 13.00 / 14.00 13.00 / 14.00",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2165",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.2,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Nominal heat output (Pdesignh) warm climate 35 °C / 55 °C kW 5.50 / 5.20 7.00 / 7.45 13.00 / 13.00 13.00 / 13.00",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:189",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 0.8,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "Mass of Refrigerant 0,800 kg",
    "location": "subtype S2125-8, general data"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2204",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 0.8,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "Filling amount kg 0.8 0.8 1.15 1.15",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:183",
   "property": "scop",
   "label": "SCOP",
   "value": 4.99,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "SCOP 4.99 3.73",
    "location": "model S2125-8 1x230V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2172",
   "property": "scop",
   "label": "SCOP",
   "value": 5.0,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:173",
   "property": "scop",
   "label": "SCOP",
   "value": 4.11,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "SCOP 4.11 3.16",
    "location": "model S2125-8 1x230V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2180",
   "property": "scop",
   "label": "SCOP",
   "value": 4.1,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2188",
   "property": "scop",
   "label": "SCOP",
   "value": 6.3,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:184",
   "property": "scop",
   "label": "SCOP",
   "value": 3.73,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "SCOP 4.99 3.73",
    "location": "model S2125-8 1x230V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2173",
   "property": "scop",
   "label": "SCOP",
   "value": 3.7,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP average climate, 35 °C / 55 °C (Europe) 5.00 / 3.70 5.00 / 3.80 5.33 / 4.08 5.30 / 4.08",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:174",
   "property": "scop",
   "label": "SCOP",
   "value": 3.16,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "SCOP 4.11 3.16",
    "location": "model S2125-8 1x230V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:2181",
   "property": "scop",
   "label": "SCOP",
   "value": 3.2,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP cold climate, 35 °C / 55 °C 4.10 / 3.20 4.20 / 3.40 4.47 / 3.59 4.60 / 3.69",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:2189",
   "property": "scop",
   "label": "SCOP",
   "value": 4.5,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "NIBE",
    "url": "https://assetstore.nibe.se/hcms/v2.3/entity/document/905826/storage/OTA1ODI2LzAvbWFzdGVy",
    "reference": null,
    "document_date": null,
    "retrieved": "2026-10-03T19:01:52+00:00",
    "quote": "SCOP warm climate, 35 °C / 55 °C 6.30 / 4.50 6.30 / 4.60 5.98 / 4.79 6.29 / 4.78",
    "location": "page 50, technical data, column S2125-8 1x230V"
   },
   "last_verified": "2026-10-03T19:04:35+00:00"
  },
  {
   "id": "bb:value:185",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "Tbiv -10 °C -10 °C",
    "location": "model S2125-8 1x230V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:175",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model S2125-8 1x230V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:186",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "Tbiv -10 °C -10 °C",
    "location": "model S2125-8 1x230V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:176",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model S2125-8 1x230V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:187",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model S2125-8 1x230V, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:177",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model S2125-8 1x230V, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:188",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model S2125-8 1x230V, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  },
  {
   "id": "bb:value:178",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=2771&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=2846625255161427399024bb02928c81",
    "reference": "012-C700114",
    "document_date": "2021-12-30",
    "retrieved": "2026-10-03T18:31:10+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model S2125-8 1x230V, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T18:32:45+00:00"
  }
 ],
 "conflicts": [],
 "open_questions": []
}