PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application187 %HP Keymark 011-1W0924
“η s 187 % 145 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application170 %HP Keymark 011-1W0924
“η s 170 % 133 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application240 %HP Keymark 011-1W0924
“η s 240 % 175 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application145 %HP Keymark 011-1W0924
“η s 187 % 145 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application133 %HP Keymark 011-1W0924
“η s 170 % 133 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application175 %HP Keymark 011-1W0924
“η s 240 % 175 %”
Rated heat output (Prated)average climate, 35 °C application16 kWHP Keymark 011-1W0924
“Prated 16.00 kW 16.00 kW”
Rated heat output (Prated)colder climate, 35 °C application16 kWHP Keymark 011-1W0924
“Prated 16.00 kW 16.00 kW”
Rated heat output (Prated)warmer climate, 35 °C application16 kWHP Keymark 011-1W0924
“Prated 16.00 kW 16.00 kW”
Rated heat output (Prated)average climate, 55 °C application16 kWHP Keymark 011-1W0924
“Prated 16.00 kW 16.00 kW”
Rated heat output (Prated)colder climate, 55 °C application16 kWHP Keymark 011-1W0924
“Prated 16.00 kW 16.00 kW”
Rated heat output (Prated)warmer climate, 55 °C application16 kWHP Keymark 011-1W0924
“Prated 16.00 kW 16.00 kW”
Refrigerant charge—1.77 kgHP Keymark 011-1W0924
“Mass of Refrigerant 1,770 kg”
SCOPaverage climate, 35 °C application4.75 HP Keymark 011-1W0924
“SCOP 4.75 3.70”
SCOPcolder climate, 35 °C application4.33 HP Keymark 011-1W0924
“SCOP 4.33 3.40”
SCOPwarmer climate, 35 °C application6.08 HP Keymark 011-1W0924
“SCOP 6.08 4.45”
SCOPaverage climate, 55 °C application3.7 HP Keymark 011-1W0924
“SCOP 4.75 3.70”
SCOPcolder climate, 55 °C application3.4 HP Keymark 011-1W0924
“SCOP 4.33 3.40”
SCOPwarmer climate, 55 °C application4.45 HP Keymark 011-1W0924
“SCOP 6.08 4.45”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0924
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-22 °CHP Keymark 011-1W0924
“Tbiv -22 °C -22 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0924
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0924
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-22 °CHP Keymark 011-1W0924
“Tbiv -22 °C -22 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0924
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0924
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0924
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0924
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0924
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0924
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0924
“TOL 2 °C 2 °C”

Open questions