Panasonic WH-SDC0916M6E5 / WH-WXG12ME5

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family Aquarea T-CAP M Series

Machine-readable: https://bedandbot.it/p/panasonic-wh-sdc0916m6e5-wh-wxg12me5.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application186 %HP Keymark 011-1W0850
“η s 186 % 143 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application172 %HP Keymark 011-1W0850
“η s 172 % 129 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application245 %HP Keymark 011-1W0850
“η s 245 % 173 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application143 %HP Keymark 011-1W0850
“η s 186 % 143 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application129 %HP Keymark 011-1W0850
“η s 172 % 129 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application173 %HP Keymark 011-1W0850
“η s 245 % 173 %”
Rated heat output (Prated)average climate, 35 °C application12 kWHP Keymark 011-1W0850
“Prated 12.00 kW 12.00 kW”
Rated heat output (Prated)colder climate, 35 °C application12 kWHP Keymark 011-1W0850
“Prated 12.00 kW 10.00 kW”
Rated heat output (Prated)warmer climate, 35 °C application12 kWHP Keymark 011-1W0850
“Prated 12.00 kW 12.00 kW”
Rated heat output (Prated)average climate, 55 °C application12 kWHP Keymark 011-1W0850
“Prated 12.00 kW 12.00 kW”
Rated heat output (Prated)colder climate, 55 °C application10 kWHP Keymark 011-1W0850
“Prated 12.00 kW 10.00 kW”
Rated heat output (Prated)warmer climate, 55 °C application12 kWHP Keymark 011-1W0850
“Prated 12.00 kW 12.00 kW”
Refrigerant charge—1.78 kgHP Keymark 011-1W0850
“Mass of Refrigerant 1,780 kg”
SCOPaverage climate, 35 °C application4.73 HP Keymark 011-1W0850
“SCOP 4.73 3.65”
SCOPcolder climate, 35 °C application4.38 HP Keymark 011-1W0850
“SCOP 4.38 3.30”
SCOPwarmer climate, 35 °C application6.2 HP Keymark 011-1W0850
“SCOP 6.20 4.40”
SCOPaverage climate, 55 °C application3.65 HP Keymark 011-1W0850
“SCOP 4.73 3.65”
SCOPcolder climate, 55 °C application3.3 HP Keymark 011-1W0850
“SCOP 4.38 3.30”
SCOPwarmer climate, 55 °C application4.4 HP Keymark 011-1W0850
“SCOP 6.20 4.40”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0850
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-22 °CHP Keymark 011-1W0850
“Tbiv -22 °C -22 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0850
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0850
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-22 °CHP Keymark 011-1W0850
“Tbiv -22 °C -22 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0850
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0850
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0850
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0850
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0850
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0850
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0850
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.