Samsung AE050CXYDEK/EU & AE200RNWMEG/EU

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family EHS R290 Mono

Machine-readable: https://bedandbot.it/p/samsung-ae050cxydek-eu-ae200rnwmeg-eu.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application201 %HP Keymark 011-1W0686
“η s 201 % 141 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application141 %HP Keymark 011-1W0686
“η s 201 % 141 %”
Rated heat output (Prated)average climate, 35 °C application5.5 kWHP Keymark 011-1W0686
“Prated 5.50 kW 5.50 kW”
Rated heat output (Prated)average climate, 55 °C application5.5 kWHP Keymark 011-1W0686
“Prated 5.50 kW 5.50 kW”
Refrigerant charge—0.63 kgHP Keymark 011-1W0686
“Mass of Refrigerant 0,630 kg”
SCOPaverage climate, 35 °C application5.1 HP Keymark 011-1W0686
“SCOP 5.10 3.60”
SCOPaverage climate, 55 °C application3.6 HP Keymark 011-1W0686
“SCOP 5.10 3.60”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0686
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0686
“Tbiv -7 °C -7 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0686
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0686
“TOL -10 °C -10 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.