Samsung AE120CXYBEK/EU

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family EHS R290 Mono

Machine-readable: https://bedandbot.it/p/samsung-ae120cxybek-eu.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application193 %HP Keymark 011-1W0685
“η s 193 % 143 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application143 %HP Keymark 011-1W0685
“η s 193 % 143 %”
Rated heat output (Prated)average climate, 35 °C application12 kWHP Keymark 011-1W0685
“Prated 12.00 kW 12.00 kW”
Rated heat output (Prated)average climate, 55 °C application12 kWHP Keymark 011-1W0685
“Prated 12.00 kW 12.00 kW”
Refrigerant charge—1.25 kgHP Keymark 011-1W0685
“Mass of Refrigerant 1,250 kg”
SCOPaverage climate, 35 °C application4.9 HP Keymark 011-1W0685
“SCOP 4.90 3.65”
SCOPaverage climate, 55 °C application3.65 HP Keymark 011-1W0685
“SCOP 4.90 3.65”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0685
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0685
“Tbiv -7 °C -7 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0685
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0685
“TOL -10 °C -10 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.