PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application211 %HP Keymark 011-1W0973
“η s 211 % 160 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application184 %HP Keymark 011-1W0973
“η s 184 % 140 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application263 %HP Keymark 011-1W0973
“η s 263 % 188 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application160 %HP Keymark 011-1W0973
“η s 211 % 160 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application140 %HP Keymark 011-1W0973
“η s 184 % 140 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application188 %HP Keymark 011-1W0973
“η s 263 % 188 %”
Rated heat output (Prated)average climate, 35 °C application5.92 kWHP Keymark 011-1W0973
“Prated 5.92 kW 5.86 kW”
Rated heat output (Prated)colder climate, 35 °C application5.38 kWHP Keymark 011-1W0973
“Prated 5.38 kW 5.00 kW”
Rated heat output (Prated)warmer climate, 35 °C application5.47 kWHP Keymark 011-1W0973
“Prated 5.47 kW 5.57 kW”
Rated heat output (Prated)average climate, 55 °C application5.86 kWHP Keymark 011-1W0973
“Prated 5.92 kW 5.86 kW”
Rated heat output (Prated)colder climate, 55 °C application5 kWHP Keymark 011-1W0973
“Prated 5.38 kW 5.00 kW”
Rated heat output (Prated)warmer climate, 55 °C application5.57 kWHP Keymark 011-1W0973
“Prated 5.47 kW 5.57 kW”
Refrigerant charge—1.4 kgHP Keymark 011-1W0973
“Mass of Refrigerant 1,400 kg”
SCOPaverage climate, 35 °C application5.35 HP Keymark 011-1W0973
“SCOP 5.35 4.07”
SCOPcolder climate, 35 °C application4.68 HP Keymark 011-1W0973
“SCOP 4.68 3.59”
SCOPwarmer climate, 35 °C application6.64 HP Keymark 011-1W0973
“SCOP 6.64 4.78”
SCOPaverage climate, 55 °C application4.07 HP Keymark 011-1W0973
“SCOP 5.35 4.07”
SCOPcolder climate, 55 °C application3.59 HP Keymark 011-1W0973
“SCOP 4.68 3.59”
SCOPwarmer climate, 55 °C application4.78 HP Keymark 011-1W0973
“SCOP 6.64 4.78”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0973
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0973
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0973
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0973
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0973
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0973
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0973
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0973
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0973
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0973
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0973
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0973
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.