Stiebel Eltron WPL-A 07.2 Plus HK 230

air-to-water monobloc · refrigerant R290 · 3x230V 50Hz · family WPL-A .2 Plus

Machine-readable: https://bedandbot.it/p/stiebel-eltron-wpl-a-07-2-plus-hk-230.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application200 %HP Keymark 011-1W0973
“η s 200 % 158 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application182 %HP Keymark 011-1W0973
“η s 182 % 144 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application253 %HP Keymark 011-1W0973
“η s 253 % 180 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application158 %HP Keymark 011-1W0973
“η s 200 % 158 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application144 %HP Keymark 011-1W0973
“η s 182 % 144 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application180 %HP Keymark 011-1W0973
“η s 253 % 180 %”
Rated heat output (Prated)average climate, 35 °C application8.15 kWHP Keymark 011-1W0973
“Prated 8.15 kW 8.05 kW”
Rated heat output (Prated)colder climate, 35 °C application7.78 kWHP Keymark 011-1W0973
“Prated 7.78 kW 7.64 kW”
Rated heat output (Prated)warmer climate, 35 °C application4.3 kWHP Keymark 011-1W0973
“Prated 4.30 kW 4.43 kW”
Rated heat output (Prated)average climate, 55 °C application8.05 kWHP Keymark 011-1W0973
“Prated 8.15 kW 8.05 kW”
Rated heat output (Prated)colder climate, 55 °C application7.64 kWHP Keymark 011-1W0973
“Prated 7.78 kW 7.64 kW”
Rated heat output (Prated)warmer climate, 55 °C application4.43 kWHP Keymark 011-1W0973
“Prated 4.30 kW 4.43 kW”
Refrigerant charge—1.4 kgHP Keymark 011-1W0973
“Mass of Refrigerant 1,400 kg”
SCOPaverage climate, 35 °C application5.09 HP Keymark 011-1W0973
“SCOP 5.09 4.02”
SCOPcolder climate, 35 °C application4.62 HP Keymark 011-1W0973
“SCOP 4.62 3.68”
SCOPwarmer climate, 35 °C application6.39 HP Keymark 011-1W0973
“SCOP 6.39 4.58”
SCOPaverage climate, 55 °C application4.02 HP Keymark 011-1W0973
“SCOP 5.09 4.02”
SCOPcolder climate, 55 °C application3.68 HP Keymark 011-1W0973
“SCOP 4.62 3.68”
SCOPwarmer climate, 55 °C application4.58 HP Keymark 011-1W0973
“SCOP 6.39 4.58”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0973
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0973
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0973
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0973
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0973
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0973
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0973
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0973
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0973
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0973
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0973
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0973
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.