 "schema_version": 0,
 "id": "bb:product:stiebel-eltron-wpl-a-10-2-w-plus-hk-230",
 "url": "https://bedandbot.it/p/stiebel-eltron-wpl-a-10-2-w-plus-hk-230/",
 "json": "https://bedandbot.it/p/stiebel-eltron-wpl-a-10-2-w-plus-hk-230.json",
 "manufacturer": "Stiebel Eltron",
 "model_family": "WPL-A .2 Plus",
 "model_code": "WPL-A 10.2 W Plus HK 230",
 "unit_type": "air-to-water monobloc",
 "refrigerant": "R290",
 "power_supply": "n/a",
 "values": [
  {
   "id": "bb:value:6173",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 195.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "η s 195 % 157 %",
    "location": "model WPL-A 10.2 W Plus HK 230, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6163",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 175.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "η s 175 % 143 %",
    "location": "model WPL-A 10.2 W Plus HK 230, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6153",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 248.0,
   "unit": "%",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "η s 248 % 180 %",
    "location": "model WPL-A 10.2 W Plus HK 230, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6174",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 157.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "η s 195 % 157 %",
    "location": "model WPL-A 10.2 W Plus HK 230, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6164",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 143.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "η s 175 % 143 %",
    "location": "model WPL-A 10.2 W Plus HK 230, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6154",
   "property": "eta_s",
   "label": "Seasonal space heating energy efficiency (ηs)",
   "value": 180.0,
   "unit": "%",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "η s 248 % 180 %",
    "location": "model WPL-A 10.2 W Plus HK 230, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6175",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 11.66,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Prated 11.66 kW 11.50 kW",
    "location": "model WPL-A 10.2 W Plus HK 230, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6165",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 11.34,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Prated 11.34 kW 11.13 kW",
    "location": "model WPL-A 10.2 W Plus HK 230, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6155",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 5.92,
   "unit": "kW",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Prated 5.92 kW 6.14 kW",
    "location": "model WPL-A 10.2 W Plus HK 230, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6176",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 11.5,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Prated 11.66 kW 11.50 kW",
    "location": "model WPL-A 10.2 W Plus HK 230, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6166",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 11.13,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Prated 11.34 kW 11.13 kW",
    "location": "model WPL-A 10.2 W Plus HK 230, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6156",
   "property": "prated",
   "label": "Rated heat output (Prated)",
   "value": 6.14,
   "unit": "kW",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Prated 5.92 kW 6.14 kW",
    "location": "model WPL-A 10.2 W Plus HK 230, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6183",
   "property": "refrigerant_charge",
   "label": "Refrigerant charge",
   "value": 1.6,
   "unit": "kg",
   "conditions": {},
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Mass of Refrigerant 1,600 kg",
    "location": "subtype WPL-A 10.2 (W) Plus HK 230/400, general data"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6177",
   "property": "scop",
   "label": "SCOP",
   "value": 4.96,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "SCOP 4.96 3.99",
    "location": "model WPL-A 10.2 W Plus HK 230, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6167",
   "property": "scop",
   "label": "SCOP",
   "value": 4.46,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "SCOP 4.46 3.66",
    "location": "model WPL-A 10.2 W Plus HK 230, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6157",
   "property": "scop",
   "label": "SCOP",
   "value": 6.27,
   "unit": "-",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "SCOP 6.27 4.58",
    "location": "model WPL-A 10.2 W Plus HK 230, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6178",
   "property": "scop",
   "label": "SCOP",
   "value": 3.99,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "SCOP 4.96 3.99",
    "location": "model WPL-A 10.2 W Plus HK 230, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6168",
   "property": "scop",
   "label": "SCOP",
   "value": 3.66,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "SCOP 4.46 3.66",
    "location": "model WPL-A 10.2 W Plus HK 230, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6158",
   "property": "scop",
   "label": "SCOP",
   "value": 4.58,
   "unit": "-",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "SCOP 6.27 4.58",
    "location": "model WPL-A 10.2 W Plus HK 230, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6179",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -7.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Tbiv -7 °C -7 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6169",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6159",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6180",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -7.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Tbiv -7 °C -7 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6170",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": -15.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Tbiv -15 °C -15 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6160",
   "property": "tbiv",
   "label": "Bivalent temperature (Tbiv)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "Tbiv 2 °C 2 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6181",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, average climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6171",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, colder climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6161",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 35,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "TOL 2 °C 2 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, warmer climate, EN 14825, 35 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6182",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -10.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "average"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "TOL -10 °C -10 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, average climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6172",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": -22.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "colder"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "TOL -22 °C -22 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, colder climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  },
  {
   "id": "bb:value:6162",
   "property": "tol",
   "label": "Operation limit temperature (TOL)",
   "value": 2.0,
   "unit": "°C",
   "conditions": {
    "application_c": 55,
    "climate": "warmer"
   },
   "source": {
    "publisher": "HP Keymark",
    "url": "https://www.heatpumpkeymark.com/en/?type=109126&tx_pskeymark_frontend%5Bsubtype%5D=8055&tx_pskeymark_frontend%5Baction%5D=showSubtype&tx_pskeymark_frontend%5Bcontroller%5D=Frontend&cHash=b130e481d20ff9b3302944ef26581746",
    "reference": "011-1W0974",
    "document_date": "2025-02-04",
    "retrieved": "2026-10-03T19:42:01+00:00",
    "quote": "TOL 2 °C 2 °C",
    "location": "model WPL-A 10.2 W Plus HK 230, warmer climate, EN 14825, 55 °C column"
   },
   "last_verified": "2026-10-03T19:45:37+00:00"
  }
 ],
 "conflicts": [],
 "open_questions": [
  {
   "id": "q:stiebel-eltron-wpl-a-10-2-w-plus-hk-230:cop-a7w35",
   "question": "We have no manufacturer-stated heating capacity and COP at A7/W35 (EN 14511) for this unit. If you know an official datasheet or manual from the manufacturer that states them, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:stiebel-eltron-wpl-a-10-2-w-plus-hk-230:cop-a7w35",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  },
  {
   "id": "q:stiebel-eltron-wpl-a-10-2-w-plus-hk-230:max-flow-temperature",
   "question": "We have no manufacturer-stated maximum flow temperature for this unit (and the outdoor temperature down to which it is reached). If you know an official document that states it, you can submit its URL.",
   "how_to_answer": {
    "method": "POST",
    "url": "https://bedandbot.it/api/contribute",
    "content_type": "application/json",
    "body": {
     "question": "q:stiebel-eltron-wpl-a-10-2-w-plus-hk-230:max-flow-temperature",
     "source_url": "https://…",
     "value": "optional, as stated in the source",
     "unit": "optional",
     "note": "optional, max 500 characters",
     "session": "optional"
    }
   },
   "what_happens": "Submissions are stored as unverified. Nothing is published until our checks find the value in the cited source. Links to new domains are reviewed by a person first."
  }
 ]
}