PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application193 %HP Keymark 011-1W0975
“η s 193 % 157 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application173 %HP Keymark 011-1W0975
“η s 173 % 146 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application255 %HP Keymark 011-1W0975
“η s 255 % 183 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application157 %HP Keymark 011-1W0975
“η s 193 % 157 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application146 %HP Keymark 011-1W0975
“η s 173 % 146 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application183 %HP Keymark 011-1W0975
“η s 255 % 183 %”
Rated heat output (Prated)average climate, 35 °C application14.58 kWHP Keymark 011-1W0975
“Prated 14.58 kW 14.84 kW”
Rated heat output (Prated)colder climate, 35 °C application14.4 kWHP Keymark 011-1W0975
“Prated 14.40 kW 14.07 kW”
Rated heat output (Prated)warmer climate, 35 °C application8.1 kWHP Keymark 011-1W0975
“Prated 8.10 kW 8.14 kW”
Rated heat output (Prated)average climate, 55 °C application14.84 kWHP Keymark 011-1W0975
“Prated 14.58 kW 14.84 kW”
Rated heat output (Prated)colder climate, 55 °C application14.07 kWHP Keymark 011-1W0975
“Prated 14.40 kW 14.07 kW”
Rated heat output (Prated)warmer climate, 55 °C application8.14 kWHP Keymark 011-1W0975
“Prated 8.10 kW 8.14 kW”
Refrigerant charge—2.15 kgHP Keymark 011-1W0975
“Mass of Refrigerant 2,150 kg”
SCOPaverage climate, 35 °C application4.89 HP Keymark 011-1W0975
“SCOP 4.89 4.01”
SCOPcolder climate, 35 °C application4.4 HP Keymark 011-1W0975
“SCOP 4.40 3.74”
SCOPwarmer climate, 35 °C application6.46 HP Keymark 011-1W0975
“SCOP 6.46 4.65”
SCOPaverage climate, 55 °C application4.01 HP Keymark 011-1W0975
“SCOP 4.89 4.01”
SCOPcolder climate, 55 °C application3.74 HP Keymark 011-1W0975
“SCOP 4.40 3.74”
SCOPwarmer climate, 55 °C application4.65 HP Keymark 011-1W0975
“SCOP 6.46 4.65”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0975
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0975
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0975
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0975
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0975
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0975
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0975
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0975
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0975
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0975
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-22 °CHP Keymark 011-1W0975
“TOL -22 °C -22 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0975
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.