Vaillant VWL 105/6 A S2

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family aroTHERM plus

Machine-readable: https://bedandbot.it/p/vaillant-vwl-105-6-a-s2.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application196 %HP Keymark 011-1W0761
“η s 196 % 142 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application170 %HP Keymark 011-1W0761
“η s 170 % 124 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application245 %HP Keymark 011-1W0761
“η s 245 % 171 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application142 %HP Keymark 011-1W0761
“η s 196 % 142 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application124 %HP Keymark 011-1W0761
“η s 170 % 124 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application171 %HP Keymark 011-1W0761
“η s 245 % 171 %”
Rated heat output (Prated)average climate, 35 °C application8.86 kWHP Keymark 011-1W0761
“Prated 8.86 kW 9.09 kW”
Rated heat output (Prated)colder climate, 35 °C application7.61 kWHP Keymark 011-1W0761
“Prated 7.61 kW 7.38 kW”
Rated heat output (Prated)warmer climate, 35 °C application10.42 kWHP Keymark 011-1W0761
“Prated 10.42 kW 10.36 kW”
Rated heat output (Prated)average climate, 55 °C application9.09 kWHP Keymark 011-1W0761
“Prated 8.86 kW 9.09 kW”
Rated heat output (Prated)colder climate, 55 °C application7.38 kWHP Keymark 011-1W0761
“Prated 7.61 kW 7.38 kW”
Rated heat output (Prated)warmer climate, 55 °C application10.36 kWHP Keymark 011-1W0761
“Prated 10.42 kW 10.36 kW”
Refrigerant charge—1.3 kgHP Keymark 011-1W0761
“Mass of Refrigerant 1,300 kg”
SCOPaverage climate, 35 °C application4.97 HP Keymark 011-1W0761
“SCOP 4.97 3.61”
SCOPcolder climate, 35 °C application4.32 HP Keymark 011-1W0761
“SCOP 4.32 3.18”
SCOPwarmer climate, 35 °C application6.21 HP Keymark 011-1W0761
“SCOP 6.21 4.35”
SCOPaverage climate, 55 °C application3.61 HP Keymark 011-1W0761
“SCOP 4.97 3.61”
SCOPcolder climate, 55 °C application3.18 HP Keymark 011-1W0761
“SCOP 4.32 3.18”
SCOPwarmer climate, 55 °C application4.35 HP Keymark 011-1W0761
“SCOP 6.21 4.35”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0761
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-20 °CHP Keymark 011-1W0761
“Tbiv -20 °C -20 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0761
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-20 °CHP Keymark 011-1W0761
“Tbiv -20 °C -20 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0761
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0761
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.