Vaillant VWL 105/6 A

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family aroTHERM plus

Machine-readable: https://bedandbot.it/p/vaillant-vwl-105-6-a.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application198 %HP Keymark 011-1W0761
“η s 198 % 143 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application171 %HP Keymark 011-1W0761
“η s 171 % 125 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application252 %HP Keymark 011-1W0761
“η s 252 % 175 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application143 %HP Keymark 011-1W0761
“η s 198 % 143 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application125 %HP Keymark 011-1W0761
“η s 171 % 125 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application175 %HP Keymark 011-1W0761
“η s 252 % 175 %”
Rated heat output (Prated)average climate, 35 °C application8.86 kWHP Keymark 011-1W0761
“Prated 8.86 kW 9.09 kW”
Rated heat output (Prated)colder climate, 35 °C application7.61 kWHP Keymark 011-1W0761
“Prated 7.61 kW 7.38 kW”
Rated heat output (Prated)warmer climate, 35 °C application10.42 kWHP Keymark 011-1W0761
“Prated 10.42 kW 10.36 kW”
Rated heat output (Prated)average climate, 55 °C application9.09 kWHP Keymark 011-1W0761
“Prated 8.86 kW 9.09 kW”
Rated heat output (Prated)colder climate, 55 °C application7.38 kWHP Keymark 011-1W0761
“Prated 7.61 kW 7.38 kW”
Rated heat output (Prated)warmer climate, 55 °C application10.36 kWHP Keymark 011-1W0761
“Prated 10.42 kW 10.36 kW”
Refrigerant charge—1.3 kgHP Keymark 011-1W0761
“Mass of Refrigerant 1,300 kg”
SCOPaverage climate, 35 °C application5.04 HP Keymark 011-1W0761
“SCOP 5.04 3.65”
SCOPcolder climate, 35 °C application4.35 HP Keymark 011-1W0761
“SCOP 4.35 3.20”
SCOPwarmer climate, 35 °C application6.39 HP Keymark 011-1W0761
“SCOP 6.39 4.44”
SCOPaverage climate, 55 °C application3.65 HP Keymark 011-1W0761
“SCOP 5.04 3.65”
SCOPcolder climate, 55 °C application3.2 HP Keymark 011-1W0761
“SCOP 4.35 3.20”
SCOPwarmer climate, 55 °C application4.44 HP Keymark 011-1W0761
“SCOP 6.39 4.44”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0761
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-20 °CHP Keymark 011-1W0761
“Tbiv -20 °C -20 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0761
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-20 °CHP Keymark 011-1W0761
“Tbiv -20 °C -20 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0761
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0761
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”

Open questions