Vaillant VWL 105/8.1 A 400V S2

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family aroTHERM plus

Machine-readable: https://bedandbot.it/p/vaillant-vwl-105-8-1-a-400v-s2.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application200 %HP Keymark 011-1W0761
“η s 200 % 150 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application182 %HP Keymark 011-1W0761
“η s 182 % 139 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application272 %HP Keymark 011-1W0761
“η s 272 % 195 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application150 %HP Keymark 011-1W0761
“η s 200 % 150 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application139 %HP Keymark 011-1W0761
“η s 182 % 139 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application195 %HP Keymark 011-1W0761
“η s 272 % 195 %”
Rated heat output (Prated)average climate, 35 °C application10.71 kWHP Keymark 011-1W0761
“Prated 10.71 kW 11.25 kW”
Rated heat output (Prated)colder climate, 35 °C application11.74 kWHP Keymark 011-1W0761
“Prated 11.74 kW 12.03 kW”
Rated heat output (Prated)warmer climate, 35 °C application13.97 kWHP Keymark 011-1W0761
“Prated 13.97 kW 13.51 kW”
Rated heat output (Prated)average climate, 55 °C application11.25 kWHP Keymark 011-1W0761
“Prated 10.71 kW 11.25 kW”
Rated heat output (Prated)colder climate, 55 °C application12.03 kWHP Keymark 011-1W0761
“Prated 11.74 kW 12.03 kW”
Rated heat output (Prated)warmer climate, 55 °C application13.51 kWHP Keymark 011-1W0761
“Prated 13.97 kW 13.51 kW”
Refrigerant charge—1.3 kgHP Keymark 011-1W0761
“Mass of Refrigerant 1,300 kg”
SCOPaverage climate, 35 °C application5.08 HP Keymark 011-1W0761
“SCOP 5.08 3.83”
SCOPcolder climate, 35 °C application4.62 HP Keymark 011-1W0761
“SCOP 4.62 3.56”
SCOPwarmer climate, 35 °C application6.87 HP Keymark 011-1W0761
“SCOP 6.87 4.96”
SCOPaverage climate, 55 °C application3.83 HP Keymark 011-1W0761
“SCOP 5.08 3.83”
SCOPcolder climate, 55 °C application3.56 HP Keymark 011-1W0761
“SCOP 4.62 3.56”
SCOPwarmer climate, 55 °C application4.96 HP Keymark 011-1W0761
“SCOP 6.87 4.96”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0761
“Tbiv -10 °C -9 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0761
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-9 °CHP Keymark 011-1W0761
“Tbiv -10 °C -9 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0761
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0761
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-21 °CHP Keymark 011-1W0761
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”