Vaillant VWL 125/6 A 230V S3

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family aroTHERM plus

Machine-readable: https://bedandbot.it/p/vaillant-vwl-125-6-a-230v-s3.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application200 %HP Keymark 011-1W0761
“η s 200 % 144 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application168 %HP Keymark 011-1W0761
“η s 168 % 126 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application256 %HP Keymark 011-1W0761
“η s 256 % 176 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application144 %HP Keymark 011-1W0761
“η s 200 % 144 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application126 %HP Keymark 011-1W0761
“η s 168 % 126 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application176 %HP Keymark 011-1W0761
“η s 256 % 176 %”
Rated heat output (Prated)average climate, 35 °C application9.35 kWHP Keymark 011-1W0761
“Prated 9.35 kW 9.66 kW”
Rated heat output (Prated)colder climate, 35 °C application10.24 kWHP Keymark 011-1W0761
“Prated 10.24 kW 10.65 kW”
Rated heat output (Prated)warmer climate, 35 °C application11.16 kWHP Keymark 011-1W0761
“Prated 11.16 kW 11.02 kW”
Rated heat output (Prated)average climate, 55 °C application9.66 kWHP Keymark 011-1W0761
“Prated 9.35 kW 9.66 kW”
Rated heat output (Prated)colder climate, 55 °C application10.65 kWHP Keymark 011-1W0761
“Prated 10.24 kW 10.65 kW”
Rated heat output (Prated)warmer climate, 55 °C application11.02 kWHP Keymark 011-1W0761
“Prated 11.16 kW 11.02 kW”
Refrigerant charge—1.3 kgHP Keymark 011-1W0761
“Mass of Refrigerant 1,300 kg”
SCOPaverage climate, 35 °C application5.07 HP Keymark 011-1W0761
“SCOP 5.07 3.67”
SCOPcolder climate, 35 °C application4.27 HP Keymark 011-1W0761
“SCOP 4.27 3.24”
SCOPwarmer climate, 35 °C application6.48 HP Keymark 011-1W0761
“SCOP 6.48 4.47”
SCOPaverage climate, 55 °C application3.67 HP Keymark 011-1W0761
“SCOP 5.07 3.67”
SCOPcolder climate, 55 °C application3.24 HP Keymark 011-1W0761
“SCOP 4.27 3.24”
SCOPwarmer climate, 55 °C application4.47 HP Keymark 011-1W0761
“SCOP 6.48 4.47”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0761
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0761
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0761
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0761
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0761
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0761
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”