PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application195 %HP Keymark 011-1W0761
“η s 195 % 147 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application170 %HP Keymark 011-1W0761
“η s 170 % 128 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application254 %HP Keymark 011-1W0761
“η s 254 % 174 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application147 %HP Keymark 011-1W0761
“η s 195 % 147 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application128 %HP Keymark 011-1W0761
“η s 170 % 128 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application174 %HP Keymark 011-1W0761
“η s 254 % 174 %”
Rated heat output (Prated)average climate, 35 °C application12.73 kWHP Keymark 011-1W0761
“Prated 12.73 kW 11.81 kW”
Rated heat output (Prated)colder climate, 35 °C application12.16 kWHP Keymark 011-1W0761
“Prated 12.16 kW 11.09 kW”
Rated heat output (Prated)warmer climate, 35 °C application11.35 kWHP Keymark 011-1W0761
“Prated 11.35 kW 11.06 kW”
Rated heat output (Prated)average climate, 55 °C application11.81 kWHP Keymark 011-1W0761
“Prated 12.73 kW 11.81 kW”
Rated heat output (Prated)colder climate, 55 °C application11.09 kWHP Keymark 011-1W0761
“Prated 12.16 kW 11.09 kW”
Rated heat output (Prated)warmer climate, 55 °C application11.06 kWHP Keymark 011-1W0761
“Prated 11.35 kW 11.06 kW”
Refrigerant charge—1.3 kgHP Keymark 011-1W0761
“Mass of Refrigerant 1,300 kg”
SCOPaverage climate, 35 °C application4.96 HP Keymark 011-1W0761
“SCOP 4.96 3.75”
SCOPcolder climate, 35 °C application4.32 HP Keymark 011-1W0761
“SCOP 4.32 3.28”
SCOPwarmer climate, 35 °C application6.41 HP Keymark 011-1W0761
“SCOP 6.41 4.42”
SCOPaverage climate, 55 °C application3.75 HP Keymark 011-1W0761
“SCOP 4.96 3.75”
SCOPcolder climate, 55 °C application3.28 HP Keymark 011-1W0761
“SCOP 4.32 3.28”
SCOPwarmer climate, 55 °C application4.42 HP Keymark 011-1W0761
“SCOP 6.41 4.42”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0761
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0761
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0761
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0761
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0761
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0761
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.