Vaillant VWL 125/8.1 A 230V S2

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family aroTHERM plus

Machine-readable: https://bedandbot.it/p/vaillant-vwl-125-8-1-a-230v-s2.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application203 %HP Keymark 011-1W0761
“η s 203 % 153 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application181 %HP Keymark 011-1W0761
“η s 181 % 135 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application270 %HP Keymark 011-1W0761
“η s 270 % 195 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application153 %HP Keymark 011-1W0761
“η s 203 % 153 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application135 %HP Keymark 011-1W0761
“η s 181 % 135 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application195 %HP Keymark 011-1W0761
“η s 270 % 195 %”
Rated heat output (Prated)average climate, 35 °C application12.19 kWHP Keymark 011-1W0761
“Prated 12.19 kW 11.92 kW”
Rated heat output (Prated)colder climate, 35 °C application12.57 kWHP Keymark 011-1W0761
“Prated 12.57 kW 12.26 kW”
Rated heat output (Prated)warmer climate, 35 °C application14.8 kWHP Keymark 011-1W0761
“Prated 14.80 kW 14.30 kW”
Rated heat output (Prated)average climate, 55 °C application11.92 kWHP Keymark 011-1W0761
“Prated 12.19 kW 11.92 kW”
Rated heat output (Prated)colder climate, 55 °C application12.26 kWHP Keymark 011-1W0761
“Prated 12.57 kW 12.26 kW”
Rated heat output (Prated)warmer climate, 55 °C application14.3 kWHP Keymark 011-1W0761
“Prated 14.80 kW 14.30 kW”
Refrigerant charge—1.3 kgHP Keymark 011-1W0761
“Mass of Refrigerant 1,300 kg”
SCOPaverage climate, 35 °C application5.15 HP Keymark 011-1W0761
“SCOP 5.15 3.91”
SCOPcolder climate, 35 °C application4.59 HP Keymark 011-1W0761
“SCOP 4.59 3.46”
SCOPwarmer climate, 35 °C application6.81 HP Keymark 011-1W0761
“SCOP 6.81 4.95”
SCOPaverage climate, 55 °C application3.91 HP Keymark 011-1W0761
“SCOP 5.15 3.91”
SCOPcolder climate, 55 °C application3.46 HP Keymark 011-1W0761
“SCOP 4.59 3.46”
SCOPwarmer climate, 55 °C application4.95 HP Keymark 011-1W0761
“SCOP 6.81 4.95”
Bivalent temperature (Tbiv)average climate, 35 °C application-9 °CHP Keymark 011-1W0761
“Tbiv -9 °C -8 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0761
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-8 °CHP Keymark 011-1W0761
“Tbiv -9 °C -8 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0761
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0761
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0761
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-21 °CHP Keymark 011-1W0761
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0761
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.