Vaillant VWL 35/6 A 230V S2

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family aroTHERM plus

Machine-readable: https://bedandbot.it/p/vaillant-vwl-35-6-a-230v-s2.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application174 %HP Keymark 011-1W0759
“η s 174 % 130 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application146 %HP Keymark 011-1W0759
“η s 146 % 108 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application200 %HP Keymark 011-1W0759
“η s 200 % 148 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application130 %HP Keymark 011-1W0759
“η s 174 % 130 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application108 %HP Keymark 011-1W0759
“η s 146 % 108 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application148 %HP Keymark 011-1W0759
“η s 200 % 148 %”
Rated heat output (Prated)average climate, 35 °C application4.19 kWHP Keymark 011-1W0759
“Prated 4.19 kW 3.40 kW”
Rated heat output (Prated)colder climate, 35 °C application3.34 kWHP Keymark 011-1W0759
“Prated 3.34 kW 3.15 kW”
Rated heat output (Prated)warmer climate, 35 °C application3.53 kWHP Keymark 011-1W0759
“Prated 3.53 kW 3.55 kW”
Rated heat output (Prated)average climate, 55 °C application3.4 kWHP Keymark 011-1W0759
“Prated 4.19 kW 3.40 kW”
Rated heat output (Prated)colder climate, 55 °C application3.15 kWHP Keymark 011-1W0759
“Prated 3.34 kW 3.15 kW”
Rated heat output (Prated)warmer climate, 55 °C application3.55 kWHP Keymark 011-1W0759
“Prated 3.53 kW 3.55 kW”
Refrigerant charge—0.6 kgHP Keymark 011-1W0759
“Mass of Refrigerant 0,600 kg”
SCOPaverage climate, 35 °C application4.43 HP Keymark 011-1W0759
“SCOP 4.43 3.33”
SCOPcolder climate, 35 °C application3.72 HP Keymark 011-1W0759
“SCOP 3.72 2.77”
SCOPwarmer climate, 35 °C application5.08 HP Keymark 011-1W0759
“SCOP 5.08 3.78”
SCOPaverage climate, 55 °C application3.33 HP Keymark 011-1W0759
“SCOP 4.43 3.33”
SCOPcolder climate, 55 °C application2.77 HP Keymark 011-1W0759
“SCOP 3.72 2.77”
SCOPwarmer climate, 55 °C application3.78 HP Keymark 011-1W0759
“SCOP 5.08 3.78”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0759
“Tbiv -7 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“Tbiv -7 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0759
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0759
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”

Open questions