PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application177 %HP Keymark 011-1W0759
“η s 177 % 132 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application147 %HP Keymark 011-1W0759
“η s 147 % 108 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application208 %HP Keymark 011-1W0759
“η s 208 % 153 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application132 %HP Keymark 011-1W0759
“η s 177 % 132 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application108 %HP Keymark 011-1W0759
“η s 147 % 108 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application153 %HP Keymark 011-1W0759
“η s 208 % 153 %”
Rated heat output (Prated)average climate, 35 °C application4.19 kWHP Keymark 011-1W0759
“Prated 4.19 kW 3.40 kW”
Rated heat output (Prated)colder climate, 35 °C application3.34 kWHP Keymark 011-1W0759
“Prated 3.34 kW 3.15 kW”
Rated heat output (Prated)warmer climate, 35 °C application3.53 kWHP Keymark 011-1W0759
“Prated 3.53 kW 3.55 kW”
Rated heat output (Prated)average climate, 55 °C application3.4 kWHP Keymark 011-1W0759
“Prated 4.19 kW 3.40 kW”
Rated heat output (Prated)colder climate, 55 °C application3.15 kWHP Keymark 011-1W0759
“Prated 3.34 kW 3.15 kW”
Rated heat output (Prated)warmer climate, 55 °C application3.55 kWHP Keymark 011-1W0759
“Prated 3.53 kW 3.55 kW”
Refrigerant charge—0.6 kgHP Keymark 011-1W0759
“Mass of Refrigerant 0,600 kg”
SCOPaverage climate, 35 °C application4.5 HP Keymark 011-1W0759
“SCOP 4.50 3.38”
SCOPcolder climate, 35 °C application3.75 HP Keymark 011-1W0759
“SCOP 3.75 2.78”
SCOPwarmer climate, 35 °C application5.29 HP Keymark 011-1W0759
“SCOP 5.29 3.89”
SCOPaverage climate, 55 °C application3.38 HP Keymark 011-1W0759
“SCOP 4.50 3.38”
SCOPcolder climate, 55 °C application2.78 HP Keymark 011-1W0759
“SCOP 3.75 2.78”
SCOPwarmer climate, 55 °C application3.89 HP Keymark 011-1W0759
“SCOP 5.29 3.89”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0759
“Tbiv -7 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“Tbiv -7 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0759
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0759
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”