Vaillant VWL 35/8.1 A 230V S2

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family aroTHERM plus

Machine-readable: https://bedandbot.it/p/vaillant-vwl-35-8-1-a-230v-s2.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application192 %HP Keymark 011-1W0759
“η s 192 % 141 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application166 %HP Keymark 011-1W0759
“η s 166 % 125 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application237 %HP Keymark 011-1W0759
“η s 237 % 173 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application141 %HP Keymark 011-1W0759
“η s 192 % 141 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application125 %HP Keymark 011-1W0759
“η s 166 % 125 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application173 %HP Keymark 011-1W0759
“η s 237 % 173 %”
Rated heat output (Prated)average climate, 35 °C application4.63 kWHP Keymark 011-1W0759
“Prated 4.63 kW 4.97 kW”
Rated heat output (Prated)colder climate, 35 °C application4.49 kWHP Keymark 011-1W0759
“Prated 4.49 kW 4.85 kW”
Rated heat output (Prated)warmer climate, 35 °C application5.39 kWHP Keymark 011-1W0759
“Prated 5.39 kW 5.15 kW”
Rated heat output (Prated)average climate, 55 °C application4.97 kWHP Keymark 011-1W0759
“Prated 4.63 kW 4.97 kW”
Rated heat output (Prated)colder climate, 55 °C application4.85 kWHP Keymark 011-1W0759
“Prated 4.49 kW 4.85 kW”
Rated heat output (Prated)warmer climate, 55 °C application5.15 kWHP Keymark 011-1W0759
“Prated 5.39 kW 5.15 kW”
Refrigerant charge—0.6 kgHP Keymark 011-1W0759
“Mass of Refrigerant 0,600 kg”
SCOPaverage climate, 35 °C application4.88 HP Keymark 011-1W0759
“SCOP 4.88 3.60”
SCOPcolder climate, 35 °C application4.21 HP Keymark 011-1W0759
“SCOP 4.21 3.21”
SCOPwarmer climate, 35 °C application6 HP Keymark 011-1W0759
“SCOP 6.00 4.39”
SCOPaverage climate, 55 °C application3.6 HP Keymark 011-1W0759
“SCOP 4.88 3.60”
SCOPcolder climate, 55 °C application3.21 HP Keymark 011-1W0759
“SCOP 4.21 3.21”
SCOPwarmer climate, 55 °C application4.39 HP Keymark 011-1W0759
“SCOP 6.00 4.39”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“Tbiv -10 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-17 °CHP Keymark 011-1W0759
“Tbiv -17 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0759
“Tbiv -10 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -17 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0759
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-21 °CHP Keymark 011-1W0759
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”

Open questions