PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application196 %HP Keymark 011-1W0759
“η s 196 % 143 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application167 %HP Keymark 011-1W0759
“η s 167 % 126 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application246 %HP Keymark 011-1W0759
“η s 246 % 178 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application143 %HP Keymark 011-1W0759
“η s 196 % 143 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application126 %HP Keymark 011-1W0759
“η s 167 % 126 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application178 %HP Keymark 011-1W0759
“η s 246 % 178 %”
Rated heat output (Prated)average climate, 35 °C application4.63 kWHP Keymark 011-1W0759
“Prated 4.63 kW 4.97 kW”
Rated heat output (Prated)colder climate, 35 °C application4.49 kWHP Keymark 011-1W0759
“Prated 4.49 kW 4.85 kW”
Rated heat output (Prated)warmer climate, 35 °C application5.39 kWHP Keymark 011-1W0759
“Prated 5.39 kW 5.15 kW”
Rated heat output (Prated)average climate, 55 °C application4.97 kWHP Keymark 011-1W0759
“Prated 4.63 kW 4.97 kW”
Rated heat output (Prated)colder climate, 55 °C application4.85 kWHP Keymark 011-1W0759
“Prated 4.49 kW 4.85 kW”
Rated heat output (Prated)warmer climate, 55 °C application5.15 kWHP Keymark 011-1W0759
“Prated 5.39 kW 5.15 kW”
Refrigerant charge—0.6 kgHP Keymark 011-1W0759
“Mass of Refrigerant 0,600 kg”
SCOPaverage climate, 35 °C application4.97 HP Keymark 011-1W0759
“SCOP 4.97 3.65”
SCOPcolder climate, 35 °C application4.25 HP Keymark 011-1W0759
“SCOP 4.25 3.23”
SCOPwarmer climate, 35 °C application6.22 HP Keymark 011-1W0759
“SCOP 6.22 4.51”
SCOPaverage climate, 55 °C application3.65 HP Keymark 011-1W0759
“SCOP 4.97 3.65”
SCOPcolder climate, 55 °C application3.23 HP Keymark 011-1W0759
“SCOP 4.25 3.23”
SCOPwarmer climate, 55 °C application4.51 HP Keymark 011-1W0759
“SCOP 6.22 4.51”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“Tbiv -10 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-17 °CHP Keymark 011-1W0759
“Tbiv -17 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0759
“Tbiv -10 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -17 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0759
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-21 °CHP Keymark 011-1W0759
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”