Vaillant VWL 55/6 A 230V S2

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family aroTHERM plus

Machine-readable: https://bedandbot.it/p/vaillant-vwl-55-6-a-230v-s2.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application181 %HP Keymark 011-1W0759
“η s 181 % 129 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application157 %HP Keymark 011-1W0759
“η s 157 % 116 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application225 %HP Keymark 011-1W0759
“η s 225 % 153 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application129 %HP Keymark 011-1W0759
“η s 181 % 129 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application116 %HP Keymark 011-1W0759
“η s 157 % 116 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application153 %HP Keymark 011-1W0759
“η s 225 % 153 %”
Rated heat output (Prated)average climate, 35 °C application4.81 kWHP Keymark 011-1W0759
“Prated 4.81 kW 4.88 kW”
Rated heat output (Prated)colder climate, 35 °C application5.01 kWHP Keymark 011-1W0759
“Prated 5.01 kW 4.76 kW”
Rated heat output (Prated)warmer climate, 35 °C application4.96 kWHP Keymark 011-1W0759
“Prated 4.96 kW 5.07 kW”
Rated heat output (Prated)average climate, 55 °C application4.88 kWHP Keymark 011-1W0759
“Prated 4.81 kW 4.88 kW”
Rated heat output (Prated)colder climate, 55 °C application4.76 kWHP Keymark 011-1W0759
“Prated 5.01 kW 4.76 kW”
Rated heat output (Prated)warmer climate, 55 °C application5.07 kWHP Keymark 011-1W0759
“Prated 4.96 kW 5.07 kW”
Refrigerant charge—0.6 kgHP Keymark 011-1W0759
“Mass of Refrigerant 0,600 kg”
SCOPaverage climate, 35 °C application4.59 HP Keymark 011-1W0759
“SCOP 4.59 3.30”
SCOPcolder climate, 35 °C application3.99 HP Keymark 011-1W0759
“SCOP 3.99 2.97”
SCOPwarmer climate, 35 °C application5.71 HP Keymark 011-1W0759
“SCOP 5.71 3.91”
SCOPaverage climate, 55 °C application3.3 HP Keymark 011-1W0759
“SCOP 4.59 3.30”
SCOPcolder climate, 55 °C application2.97 HP Keymark 011-1W0759
“SCOP 3.99 2.97”
SCOPwarmer climate, 55 °C application3.91 HP Keymark 011-1W0759
“SCOP 5.71 3.91”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0759
“Tbiv -7 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“Tbiv -7 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0759
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0759
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.