PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application177 %HP Keymark 011-1W0759
“η s 177 % 130 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application148 %HP Keymark 011-1W0759
“η s 148 % 116 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application215 %HP Keymark 011-1W0759
“η s 215 % 157 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application130 %HP Keymark 011-1W0759
“η s 177 % 130 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application116 %HP Keymark 011-1W0759
“η s 148 % 116 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application157 %HP Keymark 011-1W0759
“η s 215 % 157 %”
Rated heat output (Prated)average climate, 35 °C application4.45 kWHP Keymark 011-1W0759
“Prated 4.45 kW 4.88 kW”
Rated heat output (Prated)colder climate, 35 °C application4.68 kWHP Keymark 011-1W0759
“Prated 4.68 kW 4.76 kW”
Rated heat output (Prated)warmer climate, 35 °C application4.75 kWHP Keymark 011-1W0759
“Prated 4.75 kW 5.07 kW”
Rated heat output (Prated)average climate, 55 °C application4.88 kWHP Keymark 011-1W0759
“Prated 4.45 kW 4.88 kW”
Rated heat output (Prated)colder climate, 55 °C application4.76 kWHP Keymark 011-1W0759
“Prated 4.68 kW 4.76 kW”
Rated heat output (Prated)warmer climate, 55 °C application5.07 kWHP Keymark 011-1W0759
“Prated 4.75 kW 5.07 kW”
Refrigerant charge—0.6 kgHP Keymark 011-1W0759
“Mass of Refrigerant 0,600 kg”
SCOPaverage climate, 35 °C application4.5 HP Keymark 011-1W0759
“SCOP 4.50 3.33”
SCOPcolder climate, 35 °C application3.77 HP Keymark 011-1W0759
“SCOP 3.77 2.98”
SCOPwarmer climate, 35 °C application5.44 HP Keymark 011-1W0759
“SCOP 5.44 3.99”
SCOPaverage climate, 55 °C application3.33 HP Keymark 011-1W0759
“SCOP 4.50 3.33”
SCOPcolder climate, 55 °C application2.98 HP Keymark 011-1W0759
“SCOP 3.77 2.98”
SCOPwarmer climate, 55 °C application3.99 HP Keymark 011-1W0759
“SCOP 5.44 3.99”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0759
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0759
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”

Open questions