PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application188 %HP Keymark 011-1W0759
“η s 188 % 141 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application164 %HP Keymark 011-1W0759
“η s 164 % 126 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application238 %HP Keymark 011-1W0759
“η s 238 % 172 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application141 %HP Keymark 011-1W0759
“η s 188 % 141 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application126 %HP Keymark 011-1W0759
“η s 164 % 126 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application172 %HP Keymark 011-1W0759
“η s 238 % 172 %”
Rated heat output (Prated)average climate, 35 °C application5.6 kWHP Keymark 011-1W0759
“Prated 5.60 kW 5.64 kW”
Rated heat output (Prated)colder climate, 35 °C application5.44 kWHP Keymark 011-1W0759
“Prated 5.44 kW 5.88 kW”
Rated heat output (Prated)warmer climate, 35 °C application5.54 kWHP Keymark 011-1W0759
“Prated 5.54 kW 5.19 kW”
Rated heat output (Prated)average climate, 55 °C application5.64 kWHP Keymark 011-1W0759
“Prated 5.60 kW 5.64 kW”
Rated heat output (Prated)colder climate, 55 °C application5.88 kWHP Keymark 011-1W0759
“Prated 5.44 kW 5.88 kW”
Rated heat output (Prated)warmer climate, 55 °C application5.19 kWHP Keymark 011-1W0759
“Prated 5.54 kW 5.19 kW”
Refrigerant charge—0.6 kgHP Keymark 011-1W0759
“Mass of Refrigerant 0,600 kg”
SCOPaverage climate, 35 °C application4.76 HP Keymark 011-1W0759
“SCOP 4.76 3.60”
SCOPcolder climate, 35 °C application4.17 HP Keymark 011-1W0759
“SCOP 4.17 3.22”
SCOPwarmer climate, 35 °C application6.02 HP Keymark 011-1W0759
“SCOP 6.02 4.38”
SCOPaverage climate, 55 °C application3.6 HP Keymark 011-1W0759
“SCOP 4.76 3.60”
SCOPcolder climate, 55 °C application3.22 HP Keymark 011-1W0759
“SCOP 4.17 3.22”
SCOPwarmer climate, 55 °C application4.38 HP Keymark 011-1W0759
“SCOP 6.02 4.38”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“Tbiv -10 °C -9 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-17 °CHP Keymark 011-1W0759
“Tbiv -17 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-9 °CHP Keymark 011-1W0759
“Tbiv -10 °C -9 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0759
“Tbiv -17 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0759
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0759
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-21 °CHP Keymark 011-1W0759
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0759
“TOL 2 °C 2 °C”