PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application188 %HP Keymark 011-1W0760
“η s 188 % 131 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application162 %HP Keymark 011-1W0760
“η s 162 % 117 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application232 %HP Keymark 011-1W0760
“η s 232 % 164 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application131 %HP Keymark 011-1W0760
“η s 188 % 131 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application117 %HP Keymark 011-1W0760
“η s 162 % 117 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application164 %HP Keymark 011-1W0760
“η s 232 % 164 %”
Rated heat output (Prated)average climate, 35 °C application5.75 kWHP Keymark 011-1W0760
“Prated 5.75 kW 4.49 kW”
Rated heat output (Prated)colder climate, 35 °C application4.25 kWHP Keymark 011-1W0760
“Prated 4.25 kW 3.92 kW”
Rated heat output (Prated)warmer climate, 35 °C application5.71 kWHP Keymark 011-1W0760
“Prated 5.71 kW 6.10 kW”
Rated heat output (Prated)average climate, 55 °C application4.49 kWHP Keymark 011-1W0760
“Prated 5.75 kW 4.49 kW”
Rated heat output (Prated)colder climate, 55 °C application3.92 kWHP Keymark 011-1W0760
“Prated 4.25 kW 3.92 kW”
Rated heat output (Prated)warmer climate, 55 °C application6.1 kWHP Keymark 011-1W0760
“Prated 5.71 kW 6.10 kW”
Refrigerant charge—0.9 kgHP Keymark 011-1W0760
“Mass of Refrigerant 0,900 kg”
SCOPaverage climate, 35 °C application4.76 HP Keymark 011-1W0760
“SCOP 4.76 3.35”
SCOPcolder climate, 35 °C application4.11 HP Keymark 011-1W0760
“SCOP 4.11 3.00”
SCOPwarmer climate, 35 °C application5.87 HP Keymark 011-1W0760
“SCOP 5.87 4.16”
SCOPaverage climate, 55 °C application3.35 HP Keymark 011-1W0760
“SCOP 4.76 3.35”
SCOPcolder climate, 55 °C application3 HP Keymark 011-1W0760
“SCOP 4.11 3.00”
SCOPwarmer climate, 55 °C application4.16 HP Keymark 011-1W0760
“SCOP 5.87 4.16”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0760
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-20 °CHP Keymark 011-1W0760
“Tbiv -20 °C -20 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0760
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-10 °CHP Keymark 011-1W0760
“Tbiv -10 °C -10 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-20 °CHP Keymark 011-1W0760
“Tbiv -20 °C -20 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0760
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0760
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0760
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0760
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0760
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0760
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0760
“TOL 2 °C 2 °C”