Vaillant VWL 75/6 A 230V

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family aroTHERM plus

Machine-readable: https://bedandbot.it/p/vaillant-vwl-75-6-a-230v.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application185 %HP Keymark 011-1W0760
“η s 185 % 134 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application160 %HP Keymark 011-1W0760
“η s 160 % 118 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application237 %HP Keymark 011-1W0760
“η s 237 % 163 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application134 %HP Keymark 011-1W0760
“η s 185 % 134 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application118 %HP Keymark 011-1W0760
“η s 160 % 118 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application163 %HP Keymark 011-1W0760
“η s 237 % 163 %”
Rated heat output (Prated)average climate, 35 °C application6.6 kWHP Keymark 011-1W0760
“Prated 6.60 kW 6.13 kW”
Rated heat output (Prated)colder climate, 35 °C application5.85 kWHP Keymark 011-1W0760
“Prated 5.85 kW 5.39 kW”
Rated heat output (Prated)warmer climate, 35 °C application6.77 kWHP Keymark 011-1W0760
“Prated 6.77 kW 6.60 kW”
Rated heat output (Prated)average climate, 55 °C application6.13 kWHP Keymark 011-1W0760
“Prated 6.60 kW 6.13 kW”
Rated heat output (Prated)colder climate, 55 °C application5.39 kWHP Keymark 011-1W0760
“Prated 5.85 kW 5.39 kW”
Rated heat output (Prated)warmer climate, 55 °C application6.6 kWHP Keymark 011-1W0760
“Prated 6.77 kW 6.60 kW”
Refrigerant charge—0.9 kgHP Keymark 011-1W0760
“Mass of Refrigerant 0,900 kg”
SCOPaverage climate, 35 °C application4.69 HP Keymark 011-1W0760
“SCOP 4.69 3.43”
SCOPcolder climate, 35 °C application4.07 HP Keymark 011-1W0760
“SCOP 4.07 3.03”
SCOPwarmer climate, 35 °C application5.99 HP Keymark 011-1W0760
“SCOP 5.99 4.14”
SCOPaverage climate, 55 °C application3.43 HP Keymark 011-1W0760
“SCOP 4.69 3.43”
SCOPcolder climate, 55 °C application3.03 HP Keymark 011-1W0760
“SCOP 4.07 3.03”
SCOPwarmer climate, 55 °C application4.14 HP Keymark 011-1W0760
“SCOP 5.99 4.14”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0760
“Tbiv -10 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0760
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0760
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0760
“Tbiv -10 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0760
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0760
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0760
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0760
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0760
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0760
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0760
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0760
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.