Vaillant VWL 75/8.1 A 230V S2

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family aroTHERM plus

Machine-readable: https://bedandbot.it/p/vaillant-vwl-75-8-1-a-230v-s2.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application194 %HP Keymark 011-1W0760
“η s 194 % 141 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application174 %HP Keymark 011-1W0760
“η s 174 % 131 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application253 %HP Keymark 011-1W0760
“η s 253 % 177 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application141 %HP Keymark 011-1W0760
“η s 194 % 141 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application131 %HP Keymark 011-1W0760
“η s 174 % 131 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application177 %HP Keymark 011-1W0760
“η s 253 % 177 %”
Rated heat output (Prated)average climate, 35 °C application6.97 kWHP Keymark 011-1W0760
“Prated 6.97 kW 7.01 kW”
Rated heat output (Prated)colder climate, 35 °C application6.8 kWHP Keymark 011-1W0760
“Prated 6.80 kW 6.88 kW”
Rated heat output (Prated)warmer climate, 35 °C application6.88 kWHP Keymark 011-1W0760
“Prated 6.88 kW 6.58 kW”
Rated heat output (Prated)average climate, 55 °C application7.01 kWHP Keymark 011-1W0760
“Prated 6.97 kW 7.01 kW”
Rated heat output (Prated)colder climate, 55 °C application6.88 kWHP Keymark 011-1W0760
“Prated 6.80 kW 6.88 kW”
Rated heat output (Prated)warmer climate, 55 °C application6.58 kWHP Keymark 011-1W0760
“Prated 6.88 kW 6.58 kW”
Refrigerant charge—0.9 kgHP Keymark 011-1W0760
“Mass of Refrigerant 0,900 kg”
SCOPaverage climate, 35 °C application4.92 HP Keymark 011-1W0760
“SCOP 4.92 3.59”
SCOPcolder climate, 35 °C application4.41 HP Keymark 011-1W0760
“SCOP 4.41 3.34”
SCOPwarmer climate, 35 °C application6.4 HP Keymark 011-1W0760
“SCOP 6.40 4.50”
SCOPaverage climate, 55 °C application3.59 HP Keymark 011-1W0760
“SCOP 4.92 3.59”
SCOPcolder climate, 55 °C application3.34 HP Keymark 011-1W0760
“SCOP 4.41 3.34”
SCOPwarmer climate, 55 °C application4.5 HP Keymark 011-1W0760
“SCOP 6.40 4.50”
Bivalent temperature (Tbiv)average climate, 35 °C application-10 °CHP Keymark 011-1W0760
“Tbiv -10 °C -9 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-18 °CHP Keymark 011-1W0760
“Tbiv -18 °C -17 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0760
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-9 °CHP Keymark 011-1W0760
“Tbiv -10 °C -9 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-17 °CHP Keymark 011-1W0760
“Tbiv -18 °C -17 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0760
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0760
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-22 °CHP Keymark 011-1W0760
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0760
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0760
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-21 °CHP Keymark 011-1W0760
“TOL -22 °C -21 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0760
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.