PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application190 %HP Keymark 011-1W0776
“η s 190 % 153 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application153 %HP Keymark 011-1W0776
“η s 153 % 127 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application215 %HP Keymark 011-1W0776
“η s 215 % 159 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application153 %HP Keymark 011-1W0776
“η s 190 % 153 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application127 %HP Keymark 011-1W0776
“η s 153 % 127 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application159 %HP Keymark 011-1W0776
“η s 215 % 159 %”
Rated heat output (Prated)average climate, 35 °C application13.29 kWHP Keymark 011-1W0776
“Prated 13.29 kW 12.09 kW”
Rated heat output (Prated)colder climate, 35 °C application17.13 kWHP Keymark 011-1W0776
“Prated 17.13 kW 16.89 kW”
Rated heat output (Prated)warmer climate, 35 °C application7.24 kWHP Keymark 011-1W0776
“Prated 7.24 kW 6.77 kW”
Rated heat output (Prated)average climate, 55 °C application12.09 kWHP Keymark 011-1W0776
“Prated 13.29 kW 12.09 kW”
Rated heat output (Prated)colder climate, 55 °C application16.89 kWHP Keymark 011-1W0776
“Prated 17.13 kW 16.89 kW”
Rated heat output (Prated)warmer climate, 55 °C application6.77 kWHP Keymark 011-1W0776
“Prated 7.24 kW 6.77 kW”
Refrigerant charge—2 kgHP Keymark 011-1W0776
“Mass of Refrigerant 2,000 kg”
SCOPaverage climate, 35 °C application4.85 HP Keymark 011-1W0776
“SCOP 4.85 3.92”
SCOPcolder climate, 35 °C application3.9 HP Keymark 011-1W0776
“SCOP 3.90 3.26”
SCOPwarmer climate, 35 °C application5.46 HP Keymark 011-1W0776
“SCOP 5.46 4.05”
SCOPaverage climate, 55 °C application3.92 HP Keymark 011-1W0776
“SCOP 4.85 3.92”
SCOPcolder climate, 55 °C application3.26 HP Keymark 011-1W0776
“SCOP 3.90 3.26”
SCOPwarmer climate, 55 °C application4.05 HP Keymark 011-1W0776
“SCOP 5.46 4.05”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0776
“Tbiv -7 °C -8 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-9 °CHP Keymark 011-1W0776
“Tbiv -9 °C -9 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0776
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-8 °CHP Keymark 011-1W0776
“Tbiv -7 °C -8 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-9 °CHP Keymark 011-1W0776
“Tbiv -9 °C -9 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0776
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0776
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0776
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0776
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0776
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0776
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0776
“TOL 2 °C 2 °C”