Viessmann IDU-A Compact 2C AWMIT.A1.19-V056 / ODU 250-A AWMOF-251.A1.08-230-V002

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family Vitocal 250-A

Machine-readable: https://bedandbot.it/p/viessmann-idu-a-compact-2c-awmit-a1-19-v056-odu-250-a-awmof-251-a1-08-230-v002.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application176 %HP Keymark 011-1W0590
“η s 176 % 143 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application143 %HP Keymark 011-1W0590
“η s 143 % 123 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application238 %HP Keymark 011-1W0590
“η s 238 % 167 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application143 %HP Keymark 011-1W0590
“η s 176 % 143 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application123 %HP Keymark 011-1W0590
“η s 143 % 123 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application167 %HP Keymark 011-1W0590
“η s 238 % 167 %”
Rated heat output (Prated)average climate, 35 °C application6.47 kWHP Keymark 011-1W0590
“Prated 6.47 kW 6.20 kW”
Rated heat output (Prated)colder climate, 35 °C application7.68 kWHP Keymark 011-1W0590
“Prated 7.68 kW 7.41 kW”
Rated heat output (Prated)warmer climate, 35 °C application3.83 kWHP Keymark 011-1W0590
“Prated 3.83 kW 3.65 kW”
Rated heat output (Prated)average climate, 55 °C application6.2 kWHP Keymark 011-1W0590
“Prated 6.47 kW 6.20 kW”
Rated heat output (Prated)colder climate, 55 °C application7.41 kWHP Keymark 011-1W0590
“Prated 7.68 kW 7.41 kW”
Rated heat output (Prated)warmer climate, 55 °C application3.65 kWHP Keymark 011-1W0590
“Prated 3.83 kW 3.65 kW”
Refrigerant charge—1.2 kgHP Keymark 011-1W0590
“Mass of Refrigerant 1,200 kg”
SCOPaverage climate, 35 °C application4.44 HP Keymark 011-1W0590
“SCOP 4.44 3.66”
SCOPcolder climate, 35 °C application3.66 HP Keymark 011-1W0590
“SCOP 3.66 3.14”
SCOPwarmer climate, 35 °C application6.02 HP Keymark 011-1W0590
“SCOP 6.02 4.26”
SCOPaverage climate, 55 °C application3.66 HP Keymark 011-1W0590
“SCOP 4.44 3.66”
SCOPcolder climate, 55 °C application3.14 HP Keymark 011-1W0590
“SCOP 3.66 3.14”
SCOPwarmer climate, 55 °C application4.26 HP Keymark 011-1W0590
“SCOP 6.02 4.26”
Bivalent temperature (Tbiv)average climate, 35 °C application-6 °CHP Keymark 011-1W0590
“Tbiv -6 °C -6 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-9 °CHP Keymark 011-1W0590
“Tbiv -9 °C -9 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0590
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-6 °CHP Keymark 011-1W0590
“Tbiv -6 °C -6 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-9 °CHP Keymark 011-1W0590
“Tbiv -9 °C -9 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0590
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0590
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0590
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0590
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0590
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0590
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0590
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.