Viessmann IDU-A Modular AWMIW.A1.19-V051 / ODU 150-A AWMOF-151.A1.10-230-V001

air-to-water monobloc · refrigerant R290 · 1x230V 50Hz · family Vitocal 250-A

Machine-readable: https://bedandbot.it/p/viessmann-idu-a-modular-awmiw-a1-19-v051-odu-150-a-awmof-151-a1-10-230-v001.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application190 %HP Keymark 011-1W0465
“η s 190 % 145 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application160 %HP Keymark 011-1W0465
“η s 160 % 127 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application239 %HP Keymark 011-1W0465
“η s 239 % 168 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application145 %HP Keymark 011-1W0465
“η s 190 % 145 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application127 %HP Keymark 011-1W0465
“η s 160 % 127 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application168 %HP Keymark 011-1W0465
“η s 239 % 168 %”
Rated heat output (Prated)average climate, 35 °C application9.8 kWHP Keymark 011-1W0465
“Prated 9.80 kW 9.37 kW”
Rated heat output (Prated)colder climate, 35 °C application8.48 kWHP Keymark 011-1W0465
“Prated 8.48 kW 7.98 kW”
Rated heat output (Prated)warmer climate, 35 °C application5.27 kWHP Keymark 011-1W0465
“Prated 5.27 kW 4.65 kW”
Rated heat output (Prated)average climate, 55 °C application9.37 kWHP Keymark 011-1W0465
“Prated 9.80 kW 9.37 kW”
Rated heat output (Prated)colder climate, 55 °C application7.98 kWHP Keymark 011-1W0465
“Prated 8.48 kW 7.98 kW”
Rated heat output (Prated)warmer climate, 55 °C application4.65 kWHP Keymark 011-1W0465
“Prated 5.27 kW 4.65 kW”
Refrigerant charge—2 kgHP Keymark 011-1W0465
“Mass of Refrigerant 2,000 kg”
SCOPaverage climate, 35 °C application4.83 HP Keymark 011-1W0465
“SCOP 4.83 3.70”
SCOPcolder climate, 35 °C application4.08 HP Keymark 011-1W0465
“SCOP 4.08 3.25”
SCOPwarmer climate, 35 °C application6.04 HP Keymark 011-1W0465
“SCOP 6.04 4.27”
SCOPaverage climate, 55 °C application3.7 HP Keymark 011-1W0465
“SCOP 4.83 3.70”
SCOPcolder climate, 55 °C application3.25 HP Keymark 011-1W0465
“SCOP 4.08 3.25”
SCOPwarmer climate, 55 °C application4.27 HP Keymark 011-1W0465
“SCOP 6.04 4.27”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0465
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0465
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0465
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0465
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0465
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0465
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0465
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0465
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0465
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0465
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0465
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0465
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.