Viessmann Vitocal 150-A AWO-E-AC-AF 151.A13

air-to-water monobloc · refrigerant R290 · 3x400V 50Hz · family Vitocal 250-A

Machine-readable: https://bedandbot.it/p/viessmann-vitocal-150-a-awo-e-ac-af-151-a13.json

PropertyConditionsValueSource
Seasonal space heating energy efficiency (ηs)average climate, 35 °C application178 %HP Keymark 011-1W0465
“η s 178 % 141 %”
Seasonal space heating energy efficiency (ηs)colder climate, 35 °C application144 %HP Keymark 011-1W0465
“η s 144 % 118 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 35 °C application239 %HP Keymark 011-1W0465
“η s 239 % 173 %”
Seasonal space heating energy efficiency (ηs)average climate, 55 °C application141 %HP Keymark 011-1W0465
“η s 178 % 141 %”
Seasonal space heating energy efficiency (ηs)colder climate, 55 °C application118 %HP Keymark 011-1W0465
“η s 144 % 118 %”
Seasonal space heating energy efficiency (ηs)warmer climate, 55 °C application173 %HP Keymark 011-1W0465
“η s 239 % 173 %”
Rated heat output (Prated)average climate, 35 °C application12.42 kWHP Keymark 011-1W0465
“Prated 12.42 kW 12.10 kW”
Rated heat output (Prated)colder climate, 35 °C application10.8 kWHP Keymark 011-1W0465
“Prated 10.80 kW 10.35 kW”
Rated heat output (Prated)warmer climate, 35 °C application6.68 kWHP Keymark 011-1W0465
“Prated 6.68 kW 6.62 kW”
Rated heat output (Prated)average climate, 55 °C application12.1 kWHP Keymark 011-1W0465
“Prated 12.42 kW 12.10 kW”
Rated heat output (Prated)colder climate, 55 °C application10.35 kWHP Keymark 011-1W0465
“Prated 10.80 kW 10.35 kW”
Rated heat output (Prated)warmer climate, 55 °C application6.62 kWHP Keymark 011-1W0465
“Prated 6.68 kW 6.62 kW”
Refrigerant charge—2 kgHP Keymark 011-1W0465
“Mass of Refrigerant 2,000 kg”
SCOPaverage climate, 35 °C application4.53 HP Keymark 011-1W0465
“SCOP 4.53 3.54”
SCOPcolder climate, 35 °C application3.67 HP Keymark 011-1W0465
“SCOP 3.67 3.03”
SCOPwarmer climate, 35 °C application6.05 HP Keymark 011-1W0465
“SCOP 6.05 4.41”
SCOPaverage climate, 55 °C application3.54 HP Keymark 011-1W0465
“SCOP 4.53 3.54”
SCOPcolder climate, 55 °C application3.03 HP Keymark 011-1W0465
“SCOP 3.67 3.03”
SCOPwarmer climate, 55 °C application4.41 HP Keymark 011-1W0465
“SCOP 6.05 4.41”
Bivalent temperature (Tbiv)average climate, 35 °C application-7 °CHP Keymark 011-1W0465
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 35 °C application-15 °CHP Keymark 011-1W0465
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 35 °C application2 °CHP Keymark 011-1W0465
“Tbiv 2 °C 2 °C”
Bivalent temperature (Tbiv)average climate, 55 °C application-7 °CHP Keymark 011-1W0465
“Tbiv -7 °C -7 °C”
Bivalent temperature (Tbiv)colder climate, 55 °C application-15 °CHP Keymark 011-1W0465
“Tbiv -15 °C -15 °C”
Bivalent temperature (Tbiv)warmer climate, 55 °C application2 °CHP Keymark 011-1W0465
“Tbiv 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 35 °C application-10 °CHP Keymark 011-1W0465
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 35 °C application-20 °CHP Keymark 011-1W0465
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 35 °C application2 °CHP Keymark 011-1W0465
“TOL 2 °C 2 °C”
Operation limit temperature (TOL)average climate, 55 °C application-10 °CHP Keymark 011-1W0465
“TOL -10 °C -10 °C”
Operation limit temperature (TOL)colder climate, 55 °C application-20 °CHP Keymark 011-1W0465
“TOL -20 °C -20 °C”
Operation limit temperature (TOL)warmer climate, 55 °C application2 °CHP Keymark 011-1W0465
“TOL 2 °C 2 °C”

Open questions

Values are copied from the cited source, with the quoted text they were read from. Seasonal values: EN 14825 (climate × application). Check the source before relying on a value.